Gold Member Since 2015
Audited Supplier
Zhengzhou Nanbei Instrument Equipment Co., Ltd.

Hardness Meter, Water Hardness Meter, Benchtop Water Hardness Meter manufacturer / supplier in China, offering Water Quality Testing Equipment Water Hardness Tester, Nb5200 Portable Digital LCD Display Ultrasonic Flaw Detector, Ce Confirmed 8000mm Longitudinal Wave Digital Portable Ultrasonic Flaw Detector and so on.

(/ )

Supplier Homepage Product Physical testing instruments Hardness Tester Water Quality Testing Equipment Water Hardness Tester

Water Quality Testing Equipment Water Hardness Tester

FOB Price: US $600-1,000 / Set
Min. Order: 1 Set
Min. Order FOB Price
1 Set US $600-1,000/ Set
Get Latest Price
Production Capacity: 1000set/Sets a Month
Transport Package: 1set
Payment Terms: L/C, T/T, D/P, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: NYD300
  • Measuring Range: Mmol/L
  • Standard: ISO
  • Mobility: Desktop
  • Rated Voltage: DC9V
  • Customized: Non-Customized
  • Electrode: 601-F
  • Parameter: Mmol/L, Mg/L (CaCO3), Mg/L (Cao), Mmol/L (Boiler)
  • Calibration: B1\B2 and B3 Calibration Solution
  • Usage: School,Research,Mining
  • Communication Software: Wh-Link
  • Specification: ISO, CE
  • HS Code: 9024102000
  • Type: Water Hardness Meter
  • Application: Water
  • Warranty: 1 Year
  • Calibrating Method: Standard Hardness Test Blocks
  • Support Language: English
  • Product Name: Water Hardness Tester
  • Interface: RS232
  • Software: Wh-Link Communication Software
  • Measure Method: Electrode Method
  • Hardness Unit: Mmol/L\Mg/L(CaCO3)\Mg/L(Cao)\Mmol/L(Boiler)/M
  • Trademark: NANBEI
  • Origin: Henan, China(Mainland)
Product Description
Water quality testing equipment water hardness tester
Portable meter for measurement of water hardness by electrode measurement method, suited in field and on site.
Product Introduction
 
Benchtop meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion).
Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use.
Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage RS232 output, etc.
Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler) and mg/L (Ca). Three options of three units: ºfH(France),ºdH (Germany)and ºeH(UK) from WH-Link communication software.
Equipped with B1,B2 and B3 calibration solution.
Equipped with WH-Link communication software, connect testing data of meter to computer.

Specification

Water Hardness

Measuring range
 
 
 
Resolution
Accuracy
Temp. compensation
Calibration Solution
 
 
 
Calibration Mode

(0 ~ 10)mmol/L;        (0 ~ 401)mg/L(Ca);
(0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree);
(0 ~ 561)mg/L(CaO);    (0 ~ 56)ºdH(German Degree);
(0 ~ 20)mmol/L(Boiler);  (0 ~ 70)ºeH (England Degree).
0.01 and 0.1 water hardness units
±5% FS
(5 ~ 50)ºC((automatic))
B1 Calibration Solution - 2.00×10-2 mmol/L
B2 Calibration Solution - 2.00×10-1 mmol/L
B3 Calibration Solution - 2.00 mmol/L
(B3Calibration Solution also can be used for the soaking solution of electrode)
(a)B1/B2 Calibration-using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler
water.
(b)Calibration-using B2 and B3 Calibration Solution,suitable forgeneral water quality.

Temperature

Measuring range
Resolution
Accuracy

0 ~ 60ºC
0.1ºC
±0.5ºC

Other Technical Parameter

Data storage
Content Storage
Communication Connector
Power
Dimension and weight
Quality and safe certificate

128 groups
serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way.
RS232
DC9V
(160×190×70)mm/750g
IISO9001:2000 and CE

working conditions

Ambient temperature
ambient humidity

(5~35)ºC
≤85%RH


Standard kits 
1. Model NYD300 water hardness meter1set
2.Model 601-S water hardness electrode( With two measruing heads and one screw plug )1pc
3. AA cell (1.5V )2pcs (included)
4.100mL hardness calibration solution ( B1, B2 and B3 )1btl/each
5.20mL test cup6pcs
6. Test cup pedestal1pc
7.Carring case1pc
8. Operation manual1 set


Optional accessories

Accessory Category

Description

Specification

Water hardness electrode

601-F water hardness electrode

Suited for measurement of total concentration of calcium ion and magnesium ion, match YD200 meter, BNC+RCA connector
   
  
  

Water hardness calibration solution

Water hardness calibration solution B1

2.00×10-2 mmol/L,500mL/250mL/100mL(bottle)

Water hardness calibration solution B2

2.00×10-1 mmol/L,500mL/250mL/100mL(bottle)

Water hardness calibration solution B3

2.00 mmol/L,500mL/250mL/100mL(bottle)


Accessories

Plasic test cup

Specification:20mL

Test cup base

Place test cup on the base
 
Portable type Water hardness meterBenchtop Water hardness meter
  

Contact person
Product Groups
Send your message to this supplier
Avatar
Ms. sarah Guo
*From:
To: Ms. sarah Guo
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category