• Fully Automatic Flame Atomic Absorption Spectrophotometer
  • Fully Automatic Flame Atomic Absorption Spectrophotometer
  • Fully Automatic Flame Atomic Absorption Spectrophotometer
  • Fully Automatic Flame Atomic Absorption Spectrophotometer
  • Fully Automatic Flame Atomic Absorption Spectrophotometer
  • Fully Automatic Flame Atomic Absorption Spectrophotometer

Fully Automatic Flame Atomic Absorption Spectrophotometer

After-sales Service: Online Permanent Technical Support
Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Spectrophotometer
Advantage: High Sensitive
Principle: Classic Spectrometer
Samples:
US$ 11642/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Products
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
AA4530F
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Customized
Name
Flame Atomic Absorption Spectrophotometer
Wavelength Range
190-900nm
Receptivity of The Wavelength
<=0.04nm
Preciseness
0.50%
Grating
1800 Lines/mm
in Flamer
Atomizer
Atomizer
Effective Glass Atomizer
Transport Package
Wooden Case
Specification
CE ISO
Trademark
NANBEI
Origin
Zhengzhou City, Henan Province, China
HS Code
9027300000
Production Capacity
100sets/Month

Product Description

Product Description

AA4530F Fully Automatic Atomic Absorption Spectrophotometer

Characteristics 
1.Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
2.Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term. 
3.Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
4.Position adjusting: the best height of the flame burner and can automatically set the front and rear positions
5.Fully automated wavelength scanning and peak searching
6.Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
7.Deuterium lamp and self-absorption background regulation 
8.Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
9.Measuring method: flame absorption method and emission method
10.Result printing: parameter printing, data result printing and diagram printing

 Fully Automatic Flame Atomic Absorption Spectrophotometer
Complete automatic controlling system 
With the help of the software, the following can be easily achieved
1.Selection of the element lamp
2.Up-down-front-rear adjustment of the lifter
3.Adjustment of the optical energy
4.Selection of the slit
5.Determination of wavelength scanning and peak searching
6.Selection of the atomizer
7.Setting of the background deduction method 
8.Controlling of the gas flow
9.Automatic flaming and flaming out 
10.Setting of the graphite furnace testing method 
 
Advanced graphite furnace temperature controlling technology
1.The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data
2.The fast heating capacity can improve the flexibility of the elements further 
3.Use the ordinary power source of 220V without need of dynamic power of 380V
4.The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
5.Three grades adjustable gas flow can accustom to more application needs  
6. Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error
 
Safe, reliable and convenient flame system    
1.Epc can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily 
2.Efficient Atomization system enables a higher sensitivity 
3.The whole operation system has a high security as the fire safety system can alarm whenever the electricity is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage. 
Detailed Photos

 

Fully Automatic Flame Atomic Absorption Spectrophotometer
Fully Automatic Flame Atomic Absorption Spectrophotometer

 
Multi-functional software workstation 
1.A workstation that is supported WINDOWS XP/2000/NT
2. The rich menu brings great convenience to the use of customer
3.Convenient conversion between different menus makes the operation more easily
4.Various analytical correction methods provide the users more choices 
5.Basic default parameter settings enable even the beginners can do the normal operation
6.Flexible storage, editing and printing methods give the user largest support 
7.Instrument configuration:
Atomic Absorption Spectrophotometer   1pc
Air compressor without noise            1pc 
PC workstation: computer, HP inkjet, apparatus operating software (the object can be prevailed on the specific configuration)
A set of accessories (including Acetylene reducing valve, one copper and manganese element lamp and air filter)

 
Fully Automatic Flame Atomic Absorption Spectrophotometer
Fully Automatic Flame Atomic Absorption Spectrophotometer

Product Parameters
Model NB-4530F
Wavelength range 190 - 900nm
Spectral bandwidth Can automatically change between 0.1nm, 0.2nm, 0.4nm, 
1.0nm and 2.0nm
 Accuracy of the wavelength ±0.15nm
Receptivity of the wavelength ≤0.04nm
 Base line stability ≤0.002A/30min (Cu)
 Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
 Preciseness 0.50%
 Grating 1800 lines/mm
In flamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand Eight lamps 
D2 background 
correction ability
When the background is 1 A, the background ability should be
 deducted not less than 50 times; 
self absorption background deduction method
Size and weight 700mm×550mm×450mm  75Kg
Power source 220V±22V  AC
 
Flame system 
1. Acetylene air burner:100mm
2.Nitrous oxide acetylene flame head:50mm
3.Ignition dynamic baseline drift:≤0.006A/30min
4.(Cu) Characteristic viscosity:≤0.025μg/ml/1%
5.Related standard deviation of the accuracy:≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml) 
6.Safety system:Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

Graphite furnace
1.The highest temperature 3000ºC
2.The largest temperature rising speed ≥2000ºC/S
3.Characteristic quantity Cd≤0.5×10-12g  Cu≤0.5×10-11g
4.Accuracy Cu≤3%  Cd≤3%
5.Size and weight 550mm×450mm×300mm 65Kg
6.Safety system  Over current protection
7.Low air pressure alarm / protection   
8.Low cooling water flow alarm/protection  
9.Power source and power 220V±22V AC 7000W
Related Products
Fully Automatic Flame Atomic Absorption Spectrophotometer
Fully Automatic Flame Atomic Absorption Spectrophotometer

 

Packaging & Shipping

Fully Automatic Flame Atomic Absorption Spectrophotometer

Company Profile

Fully Automatic Flame Atomic Absorption Spectrophotometer

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express.
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:
1.Warranty:1 year
2.We supply free part for quality problem in warranty
3.Long life technical support and service


 

Send your message to this supplier

*From:
*To:
avatar Mrs. Admin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online