High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)

Product Details
Customization: Available
After-sales Service: on Line Service
Application: Laboratory Apparatus
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
  • High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Related Product
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
AA320N
Warranty
> 1Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
New Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Polychromator
Certification
ISO9001, CE
Customized
Customized
Product Name
Atomic Absorption Spectrometers
Model
AA320n
Working Spectral Range
190-900nm.
Wavelength Accuracy
<= ±0.5n
Wavelength Repeatability
<=0.3nm (Single Direction).
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm.
Resolution
<40%.
Base Line Stability
+-0.004ABS/30min
Characteristic Concentration of Copper
<=0.04mg/Ml/1%.
Detection Limit of Copper
<=0.008mg/Ml.
Background Calibration Ability
Greater Than 30 Times.
Standby Interface
RS 232.
Instrument Power Supply
220V, 3A, 50Hz
Packing Weight
150kg
Packing Size
1250*795*765mm
Transport Package
Wooden Case
Specification
1250*795*765mm
Trademark
NANBEI
Origin
China
HS Code
9027300000
Production Capacity
300pieces/Month

Product Description

Product Description

High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)

Characteristics A:

1.Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

2.Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

3.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current
Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration

4.Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit.Therefore the light flux of double beam is enhanced.

5. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

6. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic
absorption and hydride generation.

7. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame .

8. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

Characteristics B:

1. Light-source system: Hollow cathode lamp power supply: with adjustable current Lamp power supply:with fixed current

2. Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm

3. Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.

4. Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

Detailed Photos

 

High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
 
Product Parameters
Working spectral range: 190-900nm.
Wavelength accuracy: ≤ ±0.5n.
Wavelength repeatability: ≤ 0.3nm (single direction).
Spectrum bandwidth:  0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm.
Resolution:  <40%.
Base line stability: ±0.004Abs/30min
Characteristic concentration of copper:  ≤ 0.04mg/ml/1%.
Detection limit of copper:  ≤0.008mg/ml.
Background calibration ability: Greater than 30 times.
Standby Interface: RS 232.
Instrument power supply: 220V, 3A, 50Hz
Packaging & Shipping

High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)

Related Product
High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)
High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)

 

Certifications

High Accuracy Flame Atomic Absorption Spectrophotometer Aas (AA320N)

FAQ

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

Pre-sale service
· 24hours online to ensure quick response to customers' inquiry or online message;
· Guide customers to choose the best suitable machine model;
· Offer detailed specification and competitive prices;
Contract execution
· Machine production will be arranged strictly according to the contract;
· Machine photos will be sent to you for inspection during production;
· Send customs clearance documents by DHL;
· Update latest news after delivery and prepare customs clearance;
After-sale service
· 12 months warranty except for wear parts;
· Broken spare parts (except for wear parts) will be sent for free due to quality problems;
· In time response to customers technical problems;
· New products update for customers' reference.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More