Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory

Product Details
Customization: Available
After-sales Service: on Line Service
Warranty: One Year
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
  • Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
XD8010
Element
Computer Multi Element Analyzer
Analysis
Energy Dispersive
Display
Computer Screen
Application
Quality and Technical Supervision
Frequency
50Hz, 60Hz
Performance
Automation
Function
Measurement of Harmful Trace Element
Weight
55kg
Power Source
AC220V+-10%
Customized
Customized
Product Name
Element S to U Energy Dispersive X-ray Fluorescenc
Analysis Principle
Energy Dispersive X-ray Fluorescence Analysis
X - Ray Tube(Target)
Mo
Sample
Plastic / Metal / Film / Solid / Liquid / Powder
X - Ray Tube(Tube Voltage)
(5-50)Kv
Detector
Imports From The United States Si-Pin Detector
Operating System Software
Windows XP, Windows7
Working Environment
Temperature: 30degree. Humidity70%
Power Supply
AC220V±10%, 50/60Hz
Determination Conditions
Atmospheric Environment
Transport Package
Standard Export Package
Specification
550* 450*395mm
Trademark
NANBEI
Origin
Henan
HS Code
9022199090
Production Capacity
1000sets/Month

Product Description


Element S to U Energy Dispersive X-Ray Fluorescence Spectrometer
Product Description

Introduction:

Restriction of hazardous substances contained in products with environmental regulations,such as the face in the field of electrical and electronic equipment targeted at the RoHSdirective, to the automotive sector targeted ELV directive, to the field of children's toys and other objects EN71 instruction, not only in Europe but also in increasing stringent worldwide.
NanbeiI's XD-8010, analysis speed quickly, high accuracy and good reproducibility of the sample Without damage, do not pollute the environment. These technical advantages can easily solve these limitations instructions.

Applications:
Quality and Technical Supervision(Environmental directives)
RoHS/Rohs (China)/ELF/EN71
1)Toy:
Paper, ceramics, paint, metal,etc.
2)Electrical and Electronic Materials:
Semiconductors, magnetic materials, soldering, electronic parts, etc.
3)Iron and steel, non-ferrous metals:
Alloys, precious metal, slag, ores,etc.
4)Chemical industry:
Mineral products, chemical fiber, catalysts, coatings, paints,cosmetics, etc.
5)Environment:
Soil, food, industrial waste, coal powder
6)Oil:
Oil, lubricating oil, heavy oil, polymer, etc.
7)Others:
Coating thickness measurement, coal, archeology, materials research and forensic etc.

Working Principle:
1.X-ray radiation from the primary X-ray tube, is irradiated through a collimator to the sample.
2.Primary X-ray excitation characteristics of the elements contained in the sample X-rays
through the secondary collimator into the detector
3.Processed through the detector, forming fluorescence spectroscopy data
4.Computer spectroscopy data analysis, qualitative and quantitative analysis is completed

Features:
1) Three different types of X-ray radiation safety systems, software interlocks,
hardware interlocks, and mechanical interlocks, will completely eliminate radiation
leakage under any working condition.
2) The XD-8010 features a uniquely designed optical path that minimizes distances
between the X-ray source, sample, and detector while maintaining the flexibility to
switch between a variety of filters and collimators. This significantly improves the
sensitivity, and lowers the detection limit.
3) The large volume sample chamber allows large samples to be directly analyzed
without the need for damage or pre-treatment.
4) Simple, one-button analysis using a convenient and intuitive software interface.
Professional training is not required to perform basic operation of the instrument.
5) The XD-8010 provides rapid elemental analysis of elements from S to U, with
adjustable analysis times.
6) Up to 15 combinations of filters and collimators. Filters of various thicknesses and
materials are available, as well as collimators ranging from Φ1 mm to Φ7 mm.
7) The powerful report formatting feature allows for flexible customization of the
automatically generated analysis reports. The generated reports can be saved in PDF
and Excel formats. The analysis data is automatically stored after each analysis.
Historical data and statistics can be accessed at any time from a simple query
interface.
8) Using the instrument's sample camera, you can observe the position of the sample
relative to the focus of the X-ray source. Pictures of the sample are taken when
analysis begins and can be displayed in the analysis report.
9) The software's spectra comparison tool is useful for qualitative analysis and material
identification and comparison.
10) By using proven and effective methods of qualitative and quantitative analysis, the
accuracy of the results can be assured.
11) The open and flexible calibration curve fitting feature is useful for a variety of
applications such as the detection of harmful substances.

 
Detailed Photos
Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory
Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory

 

Product Parameters

Analysis Method of Harmful Element and Quality Management Process
Harmful element analysis method

Hazardous Substances Example
Screening Analysis Detailed analysis
Hg X-ray spectroscopy AAS
Pb
Cd
Cr6+ X-ray spectroscopy
(Analysis of total Cr)
Ion chromatography
PBBs / PBDEs X-ray spectroscopy
(Analysis of total Br)
GC-MS

Application Examples
Measurement of harmful trace element in polyethylene samples, such as Cr, Br,
Cd,  Hg and Pb.
• The difference of given values and the actual values of Cr, Br,  Cd, Hg and Pb.
The difference of given values and the actual values of Cr, (Unit: ppm)
Sample Given Value Actual Value (NB-8010)
Blank 0 0
Sample 1 97.3 97.4
Sample 2 288 309.8
Sample 3 1122 1107.6
The difference of given values and the actual values of Br, (Unit: ppm)
Sample Given Value Actual Value (NB-8010)
Blank 0 0
Sample 1 90 89.7
Sample 2 280 281.3
Sample 3 1116 1114.1
The difference of given values and the actual values of Cd, (Unit: ppm)
Sample Given Value Actual Value (NB-8010)
Blank 0 0
Sample 1 8.7 9.8
Sample 2 26.7 23.8
Sample 3 107 107.5
The difference of given values and the actual values of Hg, (Unit: ppm)
Sample Given Value Actual Value (NB-8010)
Blank  0 0
Sample 1 91.5 87.5
Sample 2 271 283.5
Sample 3 1096 1089.5
The difference of given values and the actual values of Pb, (Unit: ppm)
Sample Given Value Actual Value (NB-8010)
Blank 0 0
Sample 1 93.1 91.4
Sample 2 276 283.9
Sample 3 1122 1120.3
The repeated measurement data of sample 3 Cr1122ppm, Br116ppm, Cd10ppm,
Hg1096ppm, Pb1122ppm (Unit: ppm)
  Cr    Br Cd Hg Pb
1 1128.7 1118.9 110.4 1079.5 1109.4
2 1126.2 1119.5 110.8 1072.4 1131.8
3 1111.5 1115.5 115.8 1068.9 1099.5
4 1122.1 1119.9 110.3 1086.0 1103.0
5 1115.6 1123.6 103.9 1080.7 1114.8
6 1136.6 1113.2 101.2 1068.8 1103.6
7 1129.5 1112.4 105.3 1079.0 1108.0
Average 1124.3 1117.6 108.2 1076.5 1110.0
Standard deviation 8.61 4.03 4.99 6.54 10.82
RSD 0.77% 0.36% 4.62% 0.61% 0.98%

Technical  Parameters
Model NB-8010
Analysis principle Energy dispersive X-ray fluorescence analysis
Elements Range S (16) - U (92) any element
Sample Plastic / metal / film / solid / liquid / powder, etc.,any size and irregular shape
X - ray tube Target Mo
Tube voltage (5-50)kV
Tube current (10-1000)uA
Sample irradiation diameter F1mm-F7mm
Filter 15 sets of composite filter is automatically selected, and the automatic conversion
Detector Imports from the United States Si-PIN detector
The data processing circuit board Imports from the United States, with the use of Si-PIN detector sets
Sample observation With 300,000-pixel CCD camera
The sample chamber size 490 (L)′430 (W)′150 (H)
Analysis method Linear linear, quadratic Code lines, strength and concentration calibration correction
Operating system software Windows XP, Windows7
Data management Excel data management, test reports, PDF / Excel format saved
Working environment Temperature:30°C. Humidity70%
Weight 55kg
Dimensions 550′450′395mm
Power supply AC220V±10%,50/60Hz
Determination conditions Atmospheric environment
Packaging & Shipping

Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory

Company Profile

Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory

Certifications

Element S to U Energy Dispersive X-ray Fluorescence Spectrometer From China Factory

FAQ

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

Pre-sale service
· 24hours online to ensure quick response to customers' inquiry or online message;
· Guide customers to choose the best suitable machine model;
· Offer detailed specification and competitive prices;
Contract execution
· Machine production will be arranged strictly according to the contract;
· Machine photos will be sent to you for inspection during production;
· Send customs clearance documents by DHL;
· Update latest news after delivery and prepare customs clearance;

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More