Customization: | Available |
---|---|
After-sales Service: | Free Spare Parts |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 4900/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Medicine Stability Equipment Environmental Climatic Temperature Humidity Test Chamber
Usage overview
Dedicated to the stability test of pharmaceutical companies to determine the expiration date of the drug, in line with the relevant requirements of ICH.FDA and the current Pharmacopoeia, accelerated, long-term, intermediate and high humidity tests, to meet the special infusion of 40 ° C, 20% RH low humidity test.
Execution and satisfaction criteria
Implementation standards: the current version of the pharmacopoeia stability test guidelines and GB/T10586-2006 related provisions
Execute and meet the following test conditions
1. Accelerated test: 40 °C ± 2 °C / 75% RH ± 5% RH
2. Intermediate condition: 30 °C ± 2 °C / 65% RH ± 5% RH
3. Long-term test: 25 °C ± 2 °C / 60% RH ± 5% RH or 30 °C ± 2 °C / 65% RH ± 5% RH
4. Special drug test: 40 ° C ± 2 ° C / 20% RH ± 3% RH
5. Meet the ICH requirements for Q1B: total illumination ≥ 1.2 × 106 LUX.hr near UV energy ≥ 200W.hr / m2
6. Light and ultraviolet radiation tests can be completed simultaneously
Illumination system for comprehensive drug light stability test chamber
- The illumination system of the comprehensive drug light stability test chamber complies with the light stability test requirements of Q1B new drug substance and new preparation in ICH, and also meets the corresponding international manufacturing standards, and meets the guiding principles of the 2010 edition of the pharmacopoeia drug stability test. A scientific method to simulate a long-term stable temperature, humidity and light stability test environment required for drug failure period assessment
Suitable for the temperature, humidity and light stability test requirements of new APIs and new formulations in the pharmaceutical industry
- The illumination system consists of a visible tube and an ultraviolet tube, which can control the visible light tube and the ultraviolet tube separately.
Single or double-layer visible light tubes or UV tubes can also be selected, and the height of the sample sample separator at the working chamber can be adjusted.
Light illuminance display monitoring and control
Breaking through the irradiance of the existing drug stability test chamber can not show and monitor the defects, reducing the irradiance attenuation caused by aging of visible light and ultraviolet lamps, resulting in errors in the stability test of the drug. The light intensity can also be adjusted infinitely according to the requirements of the user test. The company also offers third-party certified visible and ultraviolet irradiance detectors for easy viewing and calibration.
Professional UV lamp
- The professional UV lamp complies with the light stability test requirements of Q1B new API and new preparation in ICH. Compared with other UV lamps, it has the characteristics of stable quality and uniform spectral power, and the spectral power distribution of the light source does not age with the lamp. The resulting attenuation is the ability to repeat more test results.
- Use UV lamp holders that can operate in high humidity conditions
1.Temperature and Humidity | 8.Drain Plug |
2. Nameplate | 9.Over Temperature |
3. Door Handle | 10.Water Pump Power |
4. Test Port | 11. USB |
5.Water Pump Outlet | 12. power switch |
6. Filler Hole | 13.Control Switch For Comperssor |
7. Over Flow | 14.Print |
Model | NHH-150SD | NHH-250SD | NHH-500SD | NHH-800SD | NHH-1000SD | NHH-150SDP | NHH-250SDP | NHH-500SDP | NHH-800SDP | NHH-1000SDP |
Voltage | 220V/50HZ | 380V/50HZ | 220V/50HZ | 380V/50HZ | ||||||
Temp. Control range | 0 ºC~ 65 ºC / 10 ºC~ 65 ºC | |||||||||
Temperature fluctuation / uniformity | ±0.5 ºC/±2ºC | |||||||||
Humidity control range | 20~95%RH | |||||||||
Humidity deviation | ±3%RH | |||||||||
Illumination range | N/C | |||||||||
UV irradiance range(UVA) | N/C | |||||||||
Irradiation intensity monitoring spectral range | N/C | |||||||||
Refrigerated system | Two sets of independent original imported fully enclosed compressors automatically switch (800L/1000L) | |||||||||
Inner chamber size (mm) | 500*505*700 | 550*520*920 | 720*660*1080 | 900*660*1440 | 900*700*1640 | 500*505*700 | 550*520*920 | 720*660*1080 | 900*660*1440 | 900*700*1640 |
Dimension (mm) | 660*700*1475 | 720*720*1675 | 900*860*1880 | 1400*880*1700 | 1440*920*1900 | 660*700*1475 | 720*720*1675 | 900*860*1880 | 1400*880*1700 | 1440*920*1900 |
Shelves | 3 pcs | 3 pcs | 4 pcs | 4 pcs | 4 pcs | 3 pcs | 3 pcs | 4 pcs | 4 pcs | 4 pcs |
Model | NHH-150GSD | NHH-250GSD | NHH-500GSD | NHH-800GSD | NHH-1000GSD | NHH-150GSP | NHH-250GSP | NHH-500GSP | NHH-800GSP | NHH-1000GSP |
Voltage | 220V/50HZ | 380V/50HZ | 220V/50HZ | 380V/50HZ | ||||||
Temp. Control range | without illumination :0 ºC~ 65 ºC / 10 ºC~ 65 ºC with illumination :10 ºC~ 65 ºC |
|||||||||
Temperature fluctuation / uniformity | ±0.5 ºC/±2ºC | |||||||||
Humidity control range | 20~95%RH | |||||||||
Humidity deviation | ±3%RH | |||||||||
Illumination range | 0~6000Lux | |||||||||
UV irradiance range(UVA) | 0~100mw/cm² | |||||||||
Irradiation intensity monitoring spectral range | 320-400nm | |||||||||
Refrigerated system | Two sets of independent original imported fully enclosed compressors automatically switch (800L/1000L) | |||||||||
Inner chamber size (mm) | 500*505*700 | 550*520*920 | 720*660*1080 | 900*660*1440 | 900*700*1640 | 500*505*700 | 550*520*920 | 720*660*1080 | 900*660*1440 | 900*700*1640 |
Dimension (mm) | 660*700*1475 | 720*720*1675 | 900*860*1880 | 1400*880*1700 | 1440*920*1900 | 660*700*1475 | 720*720*1675 | 900*860*1880 | 1400*880*1700 | 1440*920*1900 |
Shelves | 3 pcs | 3 pcs | 4 pcs | 4 pcs | 4 pcs | 3 pcs | 3 pcs | 4 pcs | 4 pcs | 4 pcs |
Model | NHH-150GSD-UV NHH-150GSP-UV |
NHH-250GSD-UV NHH-250GSP-UV |
NHH-500GSD-UV NHH-500GSP-UV |
NHH-800GSD-UV NHH-800GSP-UV |
NHH-1000GSD-UV NHH-1000GSP-UV |
Voltage | 220V/50HZ | 220V/50HZ | 220V/50HZ | 380V/50HZ | 380V/50HZ |
Temp. Control range | without illumination :0 ºC~ 65 ºC / 10 ºC~ 65 ºC with illumination :10 ºC~ 65 ºC |
||||
Temperature fluctuation / uniformity | ±0.5 ºC/±2ºC | ||||
Humidity range/deviation | 20~95%RH / ±3%RH | ||||
Light intensity/error | Cool white fluorescence 0~6000Lux adjustable / ±500Lux, adjustable UV light intensity | ||||
Ultraviolet spectral range | 320-400nm | ||||
Meet the experimental criteria | ICH Q18 command, cool white fluorescence ≥ 1.2 × 106 LUX.hr near ultraviolet fluorescence ≥ 200W.hr / m2 | ||||
Light source configuration | Cool white fluorescent lamp (ISO10977 compliant) and UVA near ultraviolet fluorescent lamp | ||||
Standard light source | Cold white light (D65, 6500K) / UV light with wavelength range 320~400nm | ||||
Cooling System | Two sets of independent original imported fully enclosed compressors automatically switch (800L/1000L) | ||||
Volume | 150 | 250 | 500 | 800 | 1000 |
Lighting mode | Top lighting | ||||
Inner chamber size (mm) | 550*405*670 500*505*700 |
600*500*830 550*520*900 |
800*700*900 720*660*1080 |
965*580*1430 900*660*1440 |
900*580*1600 900*700*1640 |
Dimension (mm) | 690*805*1530 660*700*1475 |
740*890*1680 720*720*1675 |
1000*1100*1860 900*860*1880 |
1475*890*1780 1400*880*1700 |
1410*890*1950 1440*920*1900 |
Printer | Yes | ||||
Safety Device |
Independent temperature limit control system (dual protection), compressor overheating, overpressure and overload, water shortage protection |
Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem
Q2:OEM,ODM acceptable or not?
Absolutely Yes
Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...
Q4:Can you visit your factory online?
Absolutely no problem
Q5:Can online video inspection before shipment?
Absolutely no problem
Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem
Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express .
We can also provide reasonable solutions according to your transportation requirements
Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.
After-sale service:
Please feel free contact Angelina to get more details.