Customization: | Available |
---|---|
After-sales Service: | on Line Service |
Application: | Laboratory Apparatus |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Tabletop Spectrophotometer NBCS-820
-Compatible with reflection and transmission measurements
Tabletop spectrophotometer NBCS-820 has the advantage of excellent inter-instrument agreement, high accuracy and good replicability. It could meet your requirement for both color quality control and color matching very easily.
Brief Introduction
1. Transmission D/0 Structure and Reflection D/8 Structure
2. Double Optical Paths Spectral Analysis Technology
It could get the measurement sample data and internal environment data at the same time to make sure the testing accuracy and stability for long time running.
3. Compatible with SCI/SCE Measurement
Adopt D/8 illuminant condition recommended by the CIE to meet the color testing requirement for different industries. It could measure with SCI and SCE to see the color data change more clearly.
4. Four Testing Calibers:
It is easy to adjust the testing calibers. The largest caliber diameter reaches 25.4mm. It could test the sample with different sizes. NBCS-820 is not only suitable for testing the color of opacity sample, but also suitable for transparent or translucent sample's transmittance and turbidity.
5. Large screen display and Stand-alone operation
It could finish the sample test without connecting with the computer. Large screen display to make sure customer could see the testing result directly and clearly and it will be more convenient to set the instrument status. The color quality management software and color match software are optional according to customer's need.
6. Unique Calibration Board Design
Fix the calibration board on the testing caliber to make sure the accuracy of the white calibration and guarantee the high accuracy for measurement.
7. Flexible Test Fixture
It could fix the sample with different size and thickness on the testing port tightly in case of stray light entering to affect the testing accuracy.
Type | NBCS-820 |
Measurement Condition | Reflection: d/8(Diffused lighting, 8 degrees receiving) Compatible with SCI/SCE Measurement ISO7724/1,DIN5033 Teil7,JIS Z8722 condition C,CIE No.15,ASTM E1164) Transmission d/0(Diffused lighting, Vertical direction receiving) |
Size of integrating sphere | Φ15.2cm, Alvan diffused reflection surface coating |
Illumination Light source | CLEDs(entire wavelength balanced LED light source) |
Sensor | dual light path sensor array |
Wavelength range | 400-700nm |
Wavelength interval | 10nm |
Half spectral width | 5nm |
Reflectivity range | 0-200% |
Reflectivity resolution | 0.01% |
Observation angle | 2°/10° |
Measurement light source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 CWF,U30,DLF,NBF,TL83,TL84 |
Data being displayed | SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color error tendency, history data color simulation, manual input standard sample, generate measurement report |
Measurement time interval | 2 seconds |
Reflection Aperture | Large Aperture (LAV):2.54cm (=1inch) |
Medium Aperture (MAV):1.5cm(=0.6inch) | |
Small Aperture (SAV):0.75cmx1.0cm(0.3inch x 0.4inch) | |
Very Small Aperture (VSAV):0.3cmx0.8cm(0.12inch x 0.31inch) | |
Color space | CIE-L*a*b,L*C*h,CIE-L*u*v,XYZ,Yxy,Transmittance, Hunterlab, Munsell MI,CMYK, RGB,HSB |
Color difference formulas | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00 ΔEab(Hunter),555color classification |
Other colorimetric indices | WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness, APHA, Pt-Co, Gardner |
Repeatability | light splitting reflectivity: standard deviation within 0.08% |
color values:ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals,Maximum:0.03) | |
Interface | USB |
Data storage | mass storage |
Light source longevity | 5 years, 1.5 million tests |
Size | 583*330*304mm(L*W*H) |
Work temperature range | 15ºC-32ºC (60°F-90°F) |
Relative Humidity | 0ºC to 45ºC,relative humidity 80% or below(at 35°C ), no condensation |
Standard accessories | AC power line, color management software, drive software, USB cable, black/white calibration tube, 40*10 cuvette, cuvette support, testing report |
Optional | 40x40 cuvette |
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.Pre-sale service
· 24hours online to ensure quick response to customers' inquiry or online message;
· Guide customers to choose the best suitable machine model;
· Offer detailed specification and competitive prices;
Contract execution
· Machine production will be arranged strictly according to the contract;
· Machine photos will be sent to you for inspection during production;
· Send customs clearance documents by DHL;
· Update latest news after delivery and prepare customs clearance;
After-sale service
· 12 months warranty except for wear parts;
· Broken spare parts (except for wear parts) will be sent for free due to quality problems;
· In time response to customers technical problems;
· New products update for customers' reference.