• GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
  • GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
  • GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
  • GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
  • GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
  • GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

After-sales Service: on Line Service
Warranty: One Year
Appliance: The Analysis of Environmental Samples
Ray Type: X-Ray Spectrometer
Gaspath System: Three
Detector: FPD
Customization:

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Related Product
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GC-MS 3100
Energy Resolution
≤8%
Certification
CE, ISO
Spectrometer Detector
SDD
Stationary Phase
Liquid Solvent
Mobile Phase
Liquid
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Convetional Analytical Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
1~2mm
Column Oven
Rt+5c up to 400c
Column Temp Accuracy
Set Value (K) +-0.5%
Temp. Deviation
2 C Max
Mass Scope
1.5 - 1024 Amu
Mass Resolution
>1.5m
Electron Multiplier
0-3kv
Two Scan Modes
Scan and SIM
Mechanical Pump
2 L/S
Syringe Specification
1,5,10,25,50,100,250,500 UL
Method Type
20
Maximum Quantity
500 UL
Minimum Quantity
0.1 UL
Time Distance for Each Injection
0-9999s
Times for Each Line Injection
1-99 Times
Sample Tray Specification
110 Digit Sample Tray (or 15 Digit Sample Tray)
Transport Package
Wooden Case
Specification
550*400*300mm
Trademark
NANBEI
Origin
China

Product Description

GC-MS3100 Lab using GC-MS Mass spectrometer
 

Product Description

l Features an EI electron bombardment ion source with an independent heating system; control range of 120 - 350 ºC (adjustable).

1.Mass range: 1.5 - 1024 amu (0-300, 0-500, 0-800 amu ranges are also available)

2.Detection limit: 1pg octafluoronaphthalene, S/N 100:1

Scan speed: Adjustable, maximum 10,000 amu/sec

l Detector: High energy dynode (HED) electron multiplier

3.Vacuum system:molecular turbo pump,250 L/s

4.GC: The GC-4000A Series with capillary column, split/splitless injection system, and fully automated gas control system

5. Includes mass flow controller

l The GC-MS 3100 can be used in combination with purge and trap, thermal analysis, headspace autosampler and other pre-treatment equipment. High boiling point samples can be analyzed using a direct injection rod.

Product Parameters

GC-MS 3100, including:

1,Gas Chromatograph:

GC-4000A main machine with Flow Controller and EPC function   

Split/ Splitless injector 

Column Oven: RT+5ºC up to 400ºC

Column Temp. Accuracy: set value (K) ±0.5%

Temp. Deviation:< 2ºC max.

8-ramp programming heating 

Capillary Column: Equity TM-5, 0.25 mm ID, 30M Length, 0.25μm coating thickness

Other columns optional

GC/MS joint for Capillary

 LCD display

2,MS System:

 EI  Ionization Source (Standard), Independent Heating System, Adjustable, between 150 ~ 300ºC, CE marked.

Quadrupole mass filter

Mass Scope: 1.5 ~ 1024 amu

Mass Resolution: >1.5M

Electron Multiplier(0~3KV)

Two scan modes: SCAN and SIM

Vacuum system: Vacuum system (standard): turbo molecular pump 240 L/s; mechanical pump: 2 L/s.  

Oil mist filter, Recommended one set for each rotary pump.

3. Data Workstation 

Software

Data Board

4-DIP system (optional)

5-SI-AS-1000 Multi-function Gas Chromatography Auto Sample Injector(optional), including

Syringe  specification: 1,5,10,25,50,100,250,500 μl

Sample tray specification: 110 digit sample tray (or 15 digit sample tray)

Times for each line injection: 1-99 times

Time distance for each injection: 0-9999s

Minimum quantity:  0.1 μl

Maximum quantity: 500 μl

Method type: 20

Sampling precision: ±1%

Necessary Accessories

He gas purification filter kit (optional)

Consists of He gas purification filter attachment parts and a He Gas purification filter.

Pressure regulator for He (optional)

He gas purity better than 99.995% is required. 

With Purge and Trap and Thermal Desorption, the purity better than 99.9999% is required.

Carrier Gas Supply Pipe 5m.

Standard Sample 5pcs/Set (For EI)

Consumables and Spare Parts

Glass Insert for Split/Splitless Injection

Graphite Ferrule, 0.4 ID for middle-bore capillary

(O.D. 0.25mm or 0.32mm), column joint (10pcs/set)

Graphite Ferrule, 0.8 ID for middle-bore capillary

(O.D. 0.53mm),capillary  column joint (10pcs/set)

silicon Injection septum,

Standard type (20pcs/set)

O-RING for Capillary Insert (5pcs/set)

For low temperature

(Injection port temperature: less than 300 degrees)

 Filter Assy (Split, Purge)

FILAMENT D ASSY

Hamilton Syringe, needle 10.0μl (optional)

Packaging & Shipping

GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

Related Product
GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer
GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

 

Company Profile

GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

Certifications

GC-MS 3100 Gas Chromatograph Quadrupole Mass Spectrometer

FAQ

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online