  • LCD Display Flame Atomic Absorption Spectrophotometer
  • LCD Display Flame Atomic Absorption Spectrophotometer
  • LCD Display Flame Atomic Absorption Spectrophotometer
  • LCD Display Flame Atomic Absorption Spectrophotometer
  • LCD Display Flame Atomic Absorption Spectrophotometer
  • LCD Display Flame Atomic Absorption Spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Products
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
AA320N
Warranty
< 1Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Atomic Absorption Spectrophotometer
Wavelengths
Atomic Absorption Spectrophotometer
Dispersive Element
Atomic Absorption Spectrophotometer
Light Number
Polychromator
Certification
ISO9001, CE
Customized
Customized
Name
Atomic Absorption Spectrophotometer
Working Spectral Range
190-900nm
Wavelength Accuracy
<=+-0.5nm
Wavelength Repeatability
<=0.3nm (Singl
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Background Calibration Ability
Greater Than 30 Times.
Standby Interface
RS 232
Instrument Power Supply
220V, 3A, 50Hz
Price
Competitive
Condition
New
Transport Package
Wooden Case
Specification
CE ISO
Trademark
NANBEI
Origin
Zhengzhou City, Henan Province, China
HS Code
9027300000
Production Capacity
100sets/Month

Product Description

Product Description

AA320N  Atomic Absorption Spectrometer


Characteristics A
1.Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

2.Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

3.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
LCD Display Flame Atomic Absorption Spectrophotometer
4.Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit.Therefore the light flux of double beam is enhanced.

5.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

6.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

7.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame .

8.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

LCD Display Flame Atomic Absorption Spectrophotometer 
Characteristics B
1.Light-source system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply:with fixed current

2.Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm

3.Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.

4.Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linearregression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

Detailed Photos

LCD Display Flame Atomic Absorption Spectrophotometer
LCD Display Flame Atomic Absorption Spectrophotometer
LCD Display Flame Atomic Absorption Spectrophotometer

 

Product Parameters

Wavelength range 190~900nm
Wavelength accuracy ≤±0.5nm
Wavelength repeatability  ≤0.3nm(single direction)
Spectrum bandwidth 0.2nm,0.4nm,0.7nm,1.4nm,2.4nm,5.0nm
Resolution <40%
Base line stability ±0.004Abs/30min
Characteristic concentration of copper ≤0.04ug/ml;1%
Detection limit of copper ≤0.008ug/ml
Background calibration ability Greater than 30times
RS232 Yes
Printer Optional
Power supply 220V,50Hz
G.W. 160KG(Main instrument)
65kg(Accessories)
Package dimension 1250*800*750mm(Main instrument)
550*460*1350mm(Accessories)
 
Accessory
Main accessories supplied with the instrument: Several decades of accessories including air compressor, one piece of
Cu hollow cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.
GA3202 HGA graphite furnace system
Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12 gram.
LCD Display Flame Atomic Absorption Spectrophotometer
LCD Display Flame Atomic Absorption Spectrophotometer
 

Related Products

LCD Display Flame Atomic Absorption Spectrophotometer
LCD Display Flame Atomic Absorption Spectrophotometer

 

Packaging & Shipping

LCD Display Flame Atomic Absorption Spectrophotometer

Company Profile

LCD Display Flame Atomic Absorption Spectrophotometer

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express.
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:
1.Warranty:1 year
2.We supply free part for quality problem in warranty