AA320N flame atomic absorption spectrophotometer
Characteristics A
1.Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuteriu*m lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc.
2.It is equipped with interface for externally linking PC.
3.Good basic line stability: Double-beam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
4.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit.Therefore the light flux of double beam is enhanced.
5.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
6.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic
absorption and hydride generation.
7. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame .
8. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.
Characteristics B:
1. Light-source system: Hollow cathode lamp power supply: with adjustable current Deuteriu*m Lamp power supply:with fixed current.
2. Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm.
3. Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.
4. Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.
Accessory:
Main accessories supplied with the instrument: Several decades of accessories including air compressor, one piece of
Cu hollow cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.
GA3202 HGA graphite furnace system
Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12 gram.
Technical data:
1 Temperature range:20ºC~3000ºC
2 Light controlling temperature range:1500ºC~3000ºC
3 Heating rate:3000ºC/S
4 Graphite furnace characteristics:Cu≤1×10-10g Cd≤1×10-12g
5 Precision:Cu≤14% Cd≤5%
6 Detection limit:Cu≤2×10-12g
7 Analysis precision is superior to the national standard.
Hollow cathode lamp:
Working spectral range | 190-900nm |
Wavelength accuracy | ≤ ±0.5nm |
Wavelength repeatability | ≤ 0.3nm (single direction) |
Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base line stability | ±0.004Abs/30min |
Characteristic concentration of copper | ≤ 0.04mg/ml/1% |
Detection limit of copper | ≤0.008mg/ml |
Background calibration ability | Greater than 30 times. |
Standby Interface | RS 232 |
Instrument power supply | 220V, 3A, 50Hz |
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.Pre-sale service
· 24hours online to ensure quick response to customers' inquiry or online message;
· Guide customers to choose the best suitable machine model;
· Offer detailed specification and competitive prices;
Contract execution
· Machine production will be arranged strictly according to the contract;
· Machine photos will be sent to you for inspection during production;
· Send customs clearance documents by DHL;
· Update latest news after delivery and prepare customs clearance;
After-sale service
· 12 months warranty except for wear parts;
· Broken spare parts (except for wear parts) will be sent for free due to quality problems;
· In time response to customers technical problems;
· New products update for customers' reference.