High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

Product Details
Customization: Available
After-sales Service: on Line Service
Application: Laboratory Apparatus
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
  • High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Product
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
AA-7050
Warranty
> 1Year
Detection Method
Spectroscopic
Advantage
High Sensitive
Principle
New Spectrometer
Wavelengths
Infrared Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001, CE
Customized
Customized
Model Number
AA-7050
Size
800X540X450mm
Weight
140kg
Band Width
0.1, 0.2, 0.4, 1.0 and 2.0nm, Automatic Slit Swit
Mono-Chromator
C-T Grating Mono-Chromator
Wavelength Accuracy/ Error
=-0.1nm
Wavelength Repeatability
<=0.05nm
Optical Grating
1800 Lines/mm
Blaze Wavelength
250nm
Resolution
Better Than 0.1nm
Transport Package
Wooden Carton
Specification
800x540x450mm
Trademark
NANBEI
Origin
China
HS Code
9027300000
Production Capacity
300sets/Month

Product Description


 
Product Description

High quality flame Atomic Absorption Spectrophotometer with Ce Approved


High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

Between flame and graphite furnace, a unique graphite furnace design among others. The NB-7050 also adopts several new features including automated burner head height adjustment, graphite furnace gas saving mode and furnace camera viewing system.

NB-7050 is offered in many different configurations along with additional optional features for customers to select from!
1.Instrument configurations include:single flame, single graphite furnace, hydride generator and integrated flame and graphite furnace.
2.Three autosamplers to choose from:AS-200 flame autosampler, AS-500 graphite furnace autosampler, AS-600 flame and graphite furnace integrated autosampler.
3.Coded hollow cathode lamps completely eliminate the possibility human error in lamp installation and automates lamp detection.
4. lamp background correction and self absorption background correction can be used to ensure accurate results.
5.Improved nitrous oxide safety system and double inner gas routes to satisfy custom analysis requirements.
6.Optional super lamp power supply to provide more energy and improve the detection limit and sensitivity of As, Se, Cd, Ni, Pb among other elements.

NB-7050 is a fully automated and multi-feature atomic absorption spectrometer.It has optical sytem suspension, automated mode switching



Regardless of which NB-7050 configuration you chose for your application, we guarantee a stress-free, safe and efficient experience and simplify analysis process.
Stable and reliable flame system
1.NB-7050 uses a pure titanium flame atomization system featuring a titanium nebulizer and burner head.
2.The parts are processed using a proprietary casting method which gives them high corrosion resistance, oxidation resistance, high structural integrity, and high temperature resistance, the nitrous oxide-acetylene system ensures accurate and precise analysis of high temperature elements, such as Al,B,Vamong other elements, A safety mechanism prevents ignition if the burner head is not installed or not correctly installed.
3.The burner head height can be automatically adjusted within a range of 0-18mm to ensure the best atomization condition for each element. Optimal analysis conditions of different elements are built into the software and can be selected automatically.
4.NB-7050 is compatible with pure titanium-platinum iridium capillary nebulizers and glass nebulizers to provide more flexibility for different matrix samples.

State-of-the-art graphite furnace system.
1.NB-7050 graphite cone can be easily replaced if needed to ensure good electrode conductivity.Atomization temperature is ocntrolled optically.The system can reach heating rate of 3000C/sec, which efficiently decreases matrix interference and reduces sample loss due to less formation of molecules, and thus increases sensitivity.When using lamp background correction, the instrument will automatically configure the  lamp and optimize its position to increase the concentricity between the beam and element beam to the greatest extent, which allows for the best background correction results.
2.Graphite furnace saving gas mode reduces waste of protection gas to the greatest extent, decreases operating cost.
3.NB-7050 features unique double gas routes, inner gas route and auxiliary gas route, Auxiliary gas is controlled route through software, the addition of auxiliary gas promotes sample ashing and protects graphite tubes, allowing more firings before replacement.
4.The graphite furnace can be observed in real time through the graphite furnace viewing system which uses a camera, the whole analysis process from sample injection to atomization can be oberved by oberving the desolventizing, drying and ashing process, parameters can be optimized to obtain more accurate results, the position of injection probe and light beam can be constantly monitored to check for probe damage and alignment issues which may lead to inaccurate results.
5.Temperature correction programs for two types of graphite tubes, standard and extended lifespan tubes, are built into the software, using the extended lifespan tubes, for typical analysis of Pb, tube firings can reach>1000firings before replacement.

The graphite furnace camera helps users locate injection probe, view sample status in graphite tubes and optimize furnace temperature programming. 
Graphite furnace gas saving mode prolongs the usage time of protection gas and therefore reduces the operating cost of the instrument.
 Graphite furnace double inner gas path permits an auxiliary gas in addition to the protection gas so as to improve the ashing process and obtain better results
6. coded lamp turret can automatically identify lamp element and record element lamp usage times.
 lamp fine adjustment mechanism ensures perfect overlap of lamp and element lamp positions.
 

Multi-element analysis function and AS-600 flame/graphite furnace auto sampler are equipped to realize fully automated analysis of multiple elements.

Detailed Photos
High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

 

Product Parameters

AA-7050 Specifications
 1. Optics System
 a)  Wavelength Range: 190nm~900nm
 b)  Band Width: 0.1, 0.2, 0.4, 1.0 and 2.0nm, automatic slit switch
 c)  Mono-Chromator: C-T grating Mono-Chromator
 d)  Wavelength accuracy/ error: ±0.1nm
 e)  Wavelength repeatability: ≤0.05nm
 f)  Optical grating: 1800 lines/mm
 g)  Blaze wavelength: 250nm
 h)  Baseline stability: static state baseline≤0.002A/30min, dynamic baseline≤0.003A/30min
 i)  Resolution: better than 0.1nm
 2. Flame Method
 a)  Characteristic concentration: ≤0.02 μg/mL/1% (Cu)
 b)  Detection limit: ≤0.003 μg/ml
 c)  RSD≤0.45%
 d)  Burner head: 50mm and 100mm interchangeable full titanium burner head and full titanium nebulizer.
 e) Position adjustment: adjustable height and angles. Flame/hydride method can be switched in 1 minute.

 3. Graphite Furnace Method
a)  Characteristic concentration: ≤0.3×10-12g (Cd)
 b)  Detection limit: ≤0.2×10-12g
c)  RSD≤1.8%
 d)  Temperature control program: Max 20 ramp temperature increasing programming in step, slope or flat mode.
 e) Temperature increasing by power or optical control
 f)  Temperature increasing rate: ≥2000ºC/s by power, ≥3000ºC/s by optical control.

 4. Background Calibration 
 a) Both flame and furnace method can run background calibration. b) Background: lamp, self absorption (optional)
 c) Calibration capability: AAS has the calibration capability of more than 60 times when background absorption value is close to 1.0Abs

 5. Data Processing
 a)  Measurement methods: flame absorption, flame emission, graphite furnace and hydride.
b)  Analysis methods: linear equation, non-linear equation, added standard.
 
c)Print output: calibration curve, signal spectrogram, instrument conditions, analysis parameters and analysis results can all be automatically saved and printed.
 6. Specifications
 a)  Dimensions: 890mm (L)×567mm (W)×490mm (H), 125kg
 b)  Power: 220V 50Hz one-phase power, main unit 200W, graphite furnace 4KW.

Related Product
High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved
High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

 

Packaging & Shipping

High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

Company Profile

High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

Certifications

High Quality Flame Atomic Absorption Spectrophotometer Aas with CE Approved

FAQ

1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

 

 

Pre-sale service

· 24hours online to ensure quick response to customers' inquiry or online message;

· Guide customers to choose the best suitable machine model;

· Offer detailed specification and competitive prices;

Contract execution

· Machine production will be arranged strictly according to the contract;

· Machine photos will be sent to you for inspection during production;

· Send customs clearance documents by DHL;

· Update latest news after delivery and prepare customs clearance;

After-sale service

· 12 months warranty except for wear parts;

· Broken spare parts (except for wear parts) will be sent for free due to quality problems;

· In time response to customers technical problems;

· New products update for customers' reference.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More