• Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
  • Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
  • Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
  • Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
  • Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
  • Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

After-sales Service: Life Long Time Technical Support
Warranty: One Year
Display: Digital
Appliance: Food Analysis, Medical Research, Biochemistry
Portable: Portable
Certification: CE
Customization:

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Our Advantages
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
EC500T
Type
Conductivity Meter
Conductivity Range
0.000 μs/Cm to 2000 Ms/Cm
Resistivity Range
5.00 Ω·cm~100.00 MΩ·cm
TDS Range
0.000~1000 Ppt
Salinity Type
Nacl%
Salinity Range
(0.00~8.00)%
Temp Range
-10 to 135c, 14 to 275f
Measurement Treading Mode
Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts
Reading, Stable, Locked
Temp. Compensation
Atc, Mtc
Data Storage
1000 Groups
GLP Features
Yes
Conductivity with Temp. Probe
5-Pin Aviation Connector
USB
USB 2.0 Flash Memory Device, PC
RS 232
Printer, Scanner, Auto-Sampler
Backlight
Yes
Transport Package
Carton Case
Specification
5kg
Trademark
NANBEI
Origin
China
HS Code
9031809090
Production Capacity
1000PCS/Month

Product Description

NANBEI Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

Our Advantages

  • Color High contrast LCD touchscreen, 7.0 inches.
  • Intelligent operation system provides features including user management, calibration management, method management, data management and etc.
  • Multi-reading feature allows auto-read, timed-read and continuous-read. 
  • Automatic/Manual temperature compensation ensures accurate results.
  • Data Storage 1000 sets for each parameter (GLP-compliant).
  • Data analysis feature helps user review, compare and recalculate results.
  • Support for USB or RS-232 communication.
  • Reset feature automatically resumes all settings back to factory default options.
  • IP54 waterproof.
  • 1-5 points calibration with Standard Recognition.
  • Settable parameters, including cell constant, reference temperature (5/10/15/18/20/25°C), temperature compensation coefficient and TDS factor.
  • Temperature compensation type (none, linear, pure water).

Product Parameters

Model EC500T
Parameters EC/Temp.(Resistivity/TDS/Sal.)
Conductivity Range 0.000 μS/cm to 2000 mS/cm
Resolution 0.001 μS/cm minimum,
various with range selection
Accuracy ±0.5% FS
Reference Temperature 5, 10, 15, 18, 20, 25 ºC
Calibration Points Up to 5
Calibration Reminder Yes
Standard Recognition 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm
Resistivity Range 5.00 Ω·cm~100.00 MΩ·cm
Resolution 0.01 Ω·cm minimum
Accuracy ±0.5% FS
TDS Range 0.000~1000 ppt
Resolution 0.001 ppm minimum, changed with range
Accuracy ±0.5%FS
Salinity Type NaCl%
Range (0.00~8.00)%
Resolution 0.01%
Accuracy ±0.1%
Temperature Range -10 to 135 ºC, 14 to 275 ºF
Unit ºC, ºF
Resolution 0.1
Accuracy ±0.1
Measurement Reading Mode Auto Read (Fast, Medium, Slow), Timed, Continuous
Reading Prompts Reading, Stable, Locked
Temp. Compensation ATC, MTC
Data management Data Storage 1000 Groups
GLP Features Yes
Log Management Yes
Inputs Conductivity with Temp. Probe 5-pin aviation connector
Outputs USB USB 2.0 flash memory device, PC
RS 232 printer, scanner, auto-sampler
Display options Backlight Yes
Auto Shutdown 1~60 min, off
IP Rating IP54
Date and Time Yes
General Power AC Adapter, 100-240V AC input, DC24V output
Dimensions 220×195×68 mm
Weight 950g (2.09 lb)

 

Detailed Photos

Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer
 

Certifications

Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

Packaging & Shipping

Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

Company Profile

Nanbei Benchtop Water Conductivity Resistivity TDS Salinity Analyzer

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express .
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:

  1. Warranty : 1 year
  2. We supply free part for quality problem in warranty
  3. Long life technical support and service

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online