Medical Ethylene Oxide Sterilizer for products From China with large volume
Application range of ethylene oxide sterilizer
Nylon fiber products and others:
Medical masks, surgical gowns, protective clothing, surgical caps, brushes, gloves, bedding, pillowcases, clothing, gauze, bandages, cotton balls, skim balls, books, letters, medical cards, case records, etc.
Endoscope:
Thoracoscope, laparoscope, laryngoscope, bronchoscope, esophagoscopy, proctoscope, cystoscope urethoscope, esophageal fiberscope, duodenal fiberscope, large intestine fiberscope, vascular fiberscope, etc.
Rubber products:
Gloves, fingerstall, syringes, hemostix, infusion set, blood transfusion set, urine collection bags, test tubes, ventricular catheters, intravenous catheters, vascular catheters, cardiac catheters, sponges, pads,etc.
Apparatus and Equipment:
Surgical instruments, medical electric drills, electric saws, bone saws, bone plates, automatic suture instrument, various sutures, suture needles, artificial esophagus, artificial bones, artificial cardiac valves, artificial blood vessels, artificial lung circuits, cardiac pacemakers, pacemaker electrodes, drainage devices, etc.
Tracheal catheter, nasal catheter, tracheostomy cannula , ventilator corrugated tube, venous pressure measuring tube, oxygen mask, anesthesia bag, closed loop circuit, artificial respiration components, etc.
Product introduction:
It consists of three parts: sterilizer box, auxiliary equipment (vacuum system, heating water tank humidification system, EO system, gas circulation system, pneumatic system and exhaust gas processor), and control system.
Box:
The sterilizer box is composed of a stainless steel liner and an atomizer water tank. The material of the box must meet the vacuum pressure requirements. The sterilizer adopts water circulation heating or electric heating.
Liner material: stainless steel SUS304, the actual thickness is ≥5mm; the supplier provides the quality list and material inspection report.
Water jacket: 6mm stainless steel on both sides and top surface.
Outsourcing temperature sense of the sterilizer box: There is no obvious sense of temperature on the outside during the sterilization cycle.
Thermal insulation: rock wool thickness> 5cm, should have good thermal insulation performance during normal operation. There is no obvious warm feeling on the outside during the sterilization process.
Shell package plate: stainless steel SUS304 wire drawing plate δ=1.2mm.
Sterilizer door: single door structure, pneumatic single door seal (chute automatic sliding opening and closing door). (In case of failure during use, it should be able to be locked and sealed at all times). Sealing method: Inflatable and sealed with silicone rubber.
Monitoring equipment: pressure, humidity, and temperature monitoring devices automatically monitor in real time, with accuracy and error of ±1%.
Motor: 380V 50Hz.
Vacuum system:
The sterilization chamber is pre-vacuumed and the sterilant is discharged by the vacuum pump.
The vacuum can be pulsating or gradient.
The vacuum pipeline is made of SUS304 material.
Pressure range: -70kpa to +60kpa, holding pressure for 60min, leakage rate <0.01kpa/min.
Vacuum rate: normal pressure to -15kpa≤6min, -50kpa≤30min, -70kpa≤40min.
Heating and thermal circulation system:
The heating adopts water circulation heating or electric heating. The heating system is additionally composed of an electric heating water tank, a hot water circulation pump and corresponding pipeline valves. The water tank is made of SUS304 stainless steel, the actual thickness is ≥5mm, and the temperature sensor in the cabinet is greater than 8m³, at least 2, with fast heating speed, simple design and structure. It is more convenient to use and other advantages.
Automatic real-time temperature monitoring instrument, alarm when the set temperature is exceeded, the temperature control range in the cabinet is <65ºC, and the accuracy is ±3ºC.
Humidification system:
Equipped with automatic steam generator and corresponding pipeline composition (no direct injection of atomized water, steam partial pressure for humidification does not exceed 50KPa). The humidity sensor has at least 2 independent steam injection pipes and filters (sterilization).
The steam pipe is made of SUS304 material.
Automatic real-time monitoring, alarm when humidity exceeds the setting, humidity error in the cabinet: ±5%RH.
Ethylene oxide vaporization:
The EO vaporizer has an independent atomization pipeline, vaporization generator, and filter, which can accurately control the temperature of the EO gas entering the sterilizer to ensure sufficient ethylene oxide vaporization and sterilization effect. (The filtration rate for particles> 0.3µm is at least 99.5% and easy to disassemble) and induction device and heating system and control.
The EO injection port is equipped with an automatic injection device, and the input port is equipped with an independent temperature sensor to control the EO temperature (control accuracy ±1).
The amount of EO added is controlled by the weight measurement method, with an accuracy of 0.05Kg.
There must be a pressure sensor in the sterilizer, which can measure the EO concentration in operation, and has a circulation system.
The sterilization process ensures that the pressure is maintained at ±5KPa of the set pressure, and an independent humidity controller is used to ensure that the gaseous EO does not exceed 70°C.
Removal system:
When the sterilant is discharged, the air enters the sterilization chamber after being filtered by a filter (with a filtration rate of at least 99.5% for particles> 0.3 µm and easy to disassemble).
According to the sterilization process, filtered air can be introduced to normal pressure, and then the sterilization chamber can be evacuated, 0-99 times self-setting.
Set according to the sterilization process, and use a continuous flow of filtered air to flow through the sterilization chamber to remove ethylene oxide gas.
After the sterilization is completed, the excess EO gas in the cabinet is pumped out by the water ring vacuum pump and mixed and dissolved fully with water.
The dissolved wastewater is stored in the waste liquid tank and discharged into the sewage pipe.
Pneumatic system:
The opening and closing of all control valves and doors during the sterilization process, and the sealing and release of the door are realized by pneumatic components such as stainless steel SUS304 material pneumatic valve, SUS304 material air pipe and SUS304 material cylinder (safety).
Each valve, interface, filter and other pipe fittings and components shall meet the requirements of YY0503-2016.
Main control system:
It adopts industrial-specific PLC to automatically control all working processes and has storage and printing functions. Real-time detection and printing of monitoring and display related data such as temperature, humidity, pressure.
With power-off protection and power-off memory function, the operation before power-off can be continued after power-on.
Volume | Rated power tolerance±20% | SIZE Length*Width*Height mm | Weight Ton |
1.2m³ | 5KVA | 1500×800×1000 | 0.9 |
1.5m³ | 5KVA | 1500×850×1200 | 1.0 |
2m³ | 6KVA | 1500×1000×1400 | 1.1 |
2.5m³ | 7KVA | 1800×1000×1400 | 1.3 |
3CBM | 7KVA | 1700×1200×1500 | 1.5 |
3.5m³ | 8KV | 2000×1200×1500 | 1.8 |
4m³ | 8KV | 2500×1200×1500 | 2.0 |
5m³ | 10KVA | 2800×1200×1500 | 2.3 |
5.5m³ | 11KVA | 3100×1200×1500 | 2.0 |
6m³ | 12KVA | 3000×1200×1700 | 3.0 |
6.5m³ | 12KVA | 3000×1300×1700 | 3.3 |
7m³ | 12KVA | 3000×1400×1700 | 3.9 |
8m³ | 13KVA | 3400×1400×1700 | 4.1 |
9m³ | 14KVA | 3800×1400×1700 | 4.6 |
10m³ | 14KVA | 4000×1500×1800 | 5 |
12m³ | 15KVA | 4500×1500×1800 | 5.3 |
15m³ | 22KVA | 5800×1500×1800 | 5.5 |
20m³ | 30KVA | 6000×1750×1950 | 6.4 |
26m³ | 32KVA | 7000×1800×2100 | 7.7 |
30m³ | 32KVA | 7600×1800×2200 | 9.5 |
40m³ | 35KVA | 8500×2000×2400 | 11 |
50m³ | 40KVA | 10000×2100×2400 | 15 |
60m³ | 50KVA | 20000×2100×2400 | 18 |
Working pressure | 0kpa-60kpa | ||
Working temperature | 30ºC-50ºC | ||
Working humidity | 30%-80% | ||
Working hours | 3h-99h | ||
Remarks | The allowable error of rated power is ±20%, the size is: length×width×height, and the allowable error is ±10%. |
Door opening method | sliding doors, optional |
Inner liner material | Adopting 304 stainless steel national standard steel plate with a thickness of ≥ 6mm, the entire plate is welded using argon arc welding for flaw detection. Durable and sturdy, with an inner liner service life of more than 10 years. |
Outer box material | Made of high-quality 304 stainless steel wire drawing plate δ= 1.2mm |
Heating method | Adopting high-quality widened PTC silicone rubber plate for six sided heating, with independent temperature control in all directions, good thermal conductivity, uniform temperature, and double protection of sterilization temperature inside the tank |
Sterilizer door | Adopting a single door structure with pneumatic single door sealing (automatic smooth opening and closing of the sliding groove). If a malfunction occurs during use, it should be ensured that it is always locked and sealed. |
Sealing method: silicone rubber external inflation sealing. | |
The pressure, humidity, and temperature monitoring device automatically monitors in real-time, with an accuracy and error of ± 1%. | |
Monitoring instruments | The steam pipeline is made of SUS304 material. Equipped with an automatic steam generator and corresponding pipelines to form an independent steam injection pipeline with a filter (sterilization level). The steam pipeline is made of SUS304 material. |
Automatic real-time monitoring, exceeding the set humidity alarm, cabinet humidity error: ± 5% RH | |
Humidification system | Using 80% ethylene oxide mixed with 20% carbon dioxide, a single tank bottle is connected to the dosing port and injected into the dosing method, which is stable and efficient. |
The sterilization agent is discharged, and the air is filtered through a filter before entering the sterilization room. According to the sterilization process, filtered air can be introduced to normal pressure, and then the sterilization room can be vacuumed for 9-99 times. After sterilization is completed, the excess EO gas in the cabinet is extracted through a water ring vacuum pump and fully mixed and dissolved with water. | |
Type of sterilization agent | Equipped with a micro printing device, it can print and save sterilization records. Built in storage, capable of storing over 8000 sterilization records and alarm records. Equipped with USB sterilization data export function, it can export data with one click operation. |
Residual removal system | can automatically monitor the sterilization process in real time, and if there is a fault, it can directly display Chinese fault information and beep to prompt an alarm. |
Equipped with power outage protection and power outage memory function, it can continue to operate before power outage after an incoming call. | |
Printing and storage functions | Suitable for sterilization of items that are resistant to heat, moisture, negative pressure, and ethylene oxide gas. For example: medical devices, endoscopes, rubber and plastic products, pharmaceuticals, textiles and biological products, cultural relics archives, instruments and meters, hygiene products, etc |
alarm system |
380V |
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.