It is controlled by microcomputer to wash 48 well and 96 well microplate in experiments of Enzyme Linked Immunosorbent Assay (ELISA), Time-Resolved Immunofluorometric Assay (TRFIA) and Chemiluminescence, which are widely used in clinical diagnostic laboratories, centers for disease control and prevention, animal and plant quarantine, animal husbandry and veterinary epidemic prevention stations, biotechnological industries, food industries, environmental science, agricultural scientific research and other academic organizations.
Features:
1.Efficiency ----2 Microplates alternative, washing 2 microplates within 1 minute.
2.Reliability ---- Special Washer manifolds design and anti-clogging technology can avoid cross-contamination and blocking.
3.Regulatory compliance ---- Meet the IVD-directive 98/79/EC for Europe, CE certified.
4.Convenience ---- Easy to maintain and operate.
5.Detailed features ---- Our profession makes it easy to use.
6.Uniform dispensing, low residual volume
7.Professional design of washer manifold's interior double tanks can keep water pressure uniform. Dispense precision CV<1.5%.
8.Aspirating in multi-positions can guarantee low residual volume<0.7ul.
9.Two alternative microplate holders make speed double, which can make use of soaking time.
10.Washer manifolds work continuously, save time.
Professional anti-clogging technology
1.The control technology of pump pressure can avoid needle's clogging.
2.Wash bottle filter can keep sediments in the solution away the pipes.
3.Pre-defined rinse procedure can avoid crystallizing in the pipes.
4.Detachable manifolds makes easy to clear particles in the manifolds.
5.Special cleaning fluid or pre-defined rinse procedure when turn on or turn off can make easy to maintain the device.
Avoid cross-contamination
1.Long needle for aspirating and short needle for dispensing make waste water and solution minimally contacted.
2.Soaking and shaking can avoid fluid's adsorption.
3.Bottom holder is slope, in order that all waste water can flow along the surface and be pumped out, which can prevent microplates from contaminating.
Suitable to different sample's quantity
1.Do not need to complement the whole plate or strip when any strip or hole is empty.
2.Do not need to stop working when change plates, which enhances productivity.
3.8-way or 12- way manifolds is available according to your conditions.
Easy to operate
1.Easy to name, edit and save different wash programs.
2.Motor speed is adjustable.
3.Stop or Pause key in the board can be chosen to stop or pause during working.
4.Multi-plate can be selected by default settings or manual operation.
5.Detachable microplate holder makes easy to disinfect and maintain it.
6.Air pressure can be adjusted to keep safe via special airpressure valve.
7.Operating noise can be less than 54 dB because of silencer design.
Advanced function, well expansibility
1.100 kinds of programs can be saved.
2.The positions of dispense and aspirate manifolds are adjustable.
3.Suitable for flat, U and V-bottom microplates.
4.Coating function, 1000 microplates/ hour.
Main Technical Parameters
Model | PW-960 |
Wash head types | microplate 12 line×8 well and 8 line×12 well are available |
Dispense uniformity | CV < 1.5% |
Wash times | 1 to 99 times adjustable |
Wash lines | whole plate or 1-12 lines random combination |
Wash mode | Single plate, double plates or multi-plates |
Dispensing volume |
50-950 μl, interval 50 μl adjustable |
(May extend to 0-6000 μl interval 25 μl adjustable) | |
Wash speed | 5 seconds/plate, 140 plates /hour |
Soaking time | 0 to 999 seconds adjustable |
Shaking time | 0 to 999 seconds adjustable |
Aspirating time | 0.1-99.9 seconds adjustable, interval 0.1second |
Microplate positions | plate A and plate B |
Residual volume | <0.7μl /well |
Wash head positions adjustable |
horizontal, left, right, middle, bottom, interval of plates |
Bottle volume | 300ml and 4000 ml for solution bottle, 4000 ml for waste water bottle |
Power Supply | AC 220V 50HZ |
External Dimensions | 53.8cm (21.2 in)*42.6cm (16.8 in)*23.0cm (9.1 in) |
Net Weight | 21kg |
Note:
1. There are 3 kinds of devices: PW-960N, PW-960 and PW-960plus.
2. There is only one solution bottle for PW-960N.
3. PW-960 plus with added features:
a) Auto discharge function for waste water.
b) Water mist catching device keeps vacuum pump dry.
4. Solution bottle/waste water bottle: 300ml, 2000ml, 5000ml, 10L/ 20L
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.5
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except wear parts. You can also buy parts from us after 12months.