PF-202-C Fluoride (F-) Combined Ion Selective Electrode ISE Probe
Product Details
| Customization: | Available |
|---|---|
| Type: | Ph Electrode |
| Cooling System: | Radiator |
Diamond Member Since 2015
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Years of Export Experience
Self-branded
The supplier has import and export rights
The export experience of the supplier is more than 10 years
The supplier has 1 Self-brands, check the Audit Report for more information
Sign In to see all verified strength labels (17)
Find Similar Products
Basic Info.
- Model NO.
- PF-202-C
- Function
- Over Voltage Protection, Overheat Protection, Short Circuit Protection
- Materials
- Plastic
- Name
- Combined Ion Selective Electrode
- Species
- Fluoride (F-)
- Measuring Range
- 10-1~10-6 Mol/L
- Temperature
- 5-45 C
- Body Material
- Glass
- Size
- 12*120mm
- Connector
- BNC
- Measurement Ion
- FL, Cu, AG, Ka, Cl, Nitrite, Nitrate etc
- Temperature Compensation
- Automatic
- Package
- Carton Box
- Weight
- 0.5kg
- Membrane
- Crystalline State Membrane
- Body
- Plastic
- Work with
- Ion Meter/ Multiparameter Water Analyzer
- Measurement Mode
- Auto-Reading, Standard Add, Sample Add, Gran
- Transport Package
- Carton Box Package
- Specification
- 50g
- Trademark
- NANBEI
- Origin
- China(Mainland)
- HS Code
- 7419999100
- Production Capacity
- 20000set a Month
Product Description
PF-202-C Fluoride (F-) Combined Ion Selective Electrode / ISE probe
An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a transducer (or sensor) that converts the activity of a specific ion dissolved in a solution into an electrical potential, which can be measured by a voltmeter or pH meter. The voltage is theoretically dependent on the logarithm of the ionic activity,according to the Nernst equation.The sensing part of the electrode is usually made as an ion-specific membrane, along with a reference electrode. Ion-selective electrodes are used in biochemical and biophysical research, where measurements of ionic concentration in an aqueous solution are required,usually on a real time basis.
Applications of ISE
The analytic targetof ion selective electrode is widely. With appropriate measurement method, ion meter and electrode, it can measure corresponding ion concentration value. Now it has been successfully applied in fields like environmental monitoring, water monitoring, soil analysis, food detection and pharmaceutical analysis.
Applications of ISE in different industries
| Industry | MeasuringIon |
| Aquaculture | Ammonia,Nitrate |
| Paper making | Sodium,Chloride,Calcium |
| Steam and electric engine | Chloride,Residual chlorine,Sodium,Calcium,Ammonia |
| Agriculture | Calcium,Sodium,Potassium,Bromine,Chloride,Fluorine,Iodine, Fluorin boric acid,Nitrate,Cyanide |
| Food and beverage | Chloride,Fluorine,Iodine,Calcium |
| Metallurgy&electroplating | Copper,Fluoride,Cyanide |
| Seawater | Sodium,Chloride,Nitrate,Fluoride and Ammonia nitrogen |
| Natural water | Potassium,Calcium,Sodium,Bromine, Chloride,Fluoride,Iodine, Sliver,Nitrate |
| Drinking water | Residual chlorine,Nitrate,Fluoride,Copper |
Techincal parameter for some Ion selective probe
| Model | PF-202-C |
| Species | Fluoride (F-) |
| Name | Combined Ion Selective Electrode |
| Measuring range (mol/L) | 10-1M~10-6M |
| Membrane | Crystalline state membrane |
| Body | Plastic |
| Dimension | Φ12×120 mm |
| Working Temp. | 5~45 ºC |
| Connector | BNC(Q9) |
| PF-1 Fluoride ISE | PCl-1 Chloride ISE | ||
| Measuring range | 10-1-10-6 mol/L | Measuring range | 10-1-5x10-5 mol/L |
| Temperature range | 5-45C | Temperature range | 5-60C |
| body material | Glass | Body material | oragnic glass |
| Size | 12*120mm | Size | 12*120mm |
| Connector | BNC | Connector | BNC |
![]() |
![]() |
||
| PK-1 Potassium ISE / PCa-1 Calcium ISE / PNO3-1 NitrateISE | |
| Measuring range | 10-1-10-5 mol/L |
| Temperature range | 5-60C |
| Body material | Organic glass |
| Size | 12*120mm |
| Connector | BNC |
ISE&ProperReference Electrode
| No. | ISE | Reference electrode | Reference solution |
| 1 | PK-1 Potassium ISE | 217 Reference electrode | 0.1mol/L LiAc |
| 2 | PCa-1CalciumISE | SaturatedKNO3 | |
| 3 | PNO3-1NitrateISE |
SaturatedKCL | |
| 4 | PBF4-1 Fluoroborate ISE | ||
| 5 | PBr-1BromideISE |
SaturatedKNO3 | |
| 6 | PCN-1CyanideISE | ||
| 7 | PPb-1LeadISE | 1mol/LKNO3 | |
| 8 | PAgS-1Silver-SulfionISE | C(K2SO4)Reference Electrode9 | |
| 9 | PCl-1ChlorideISE | ||
| 10 | PCu-1CopperISE | ||
| 11 | PF-1FluorideISE | 232-01Referenceelectrode | SaturatedKCL |
| 12 | 6801-01SodiumISE | 6802-01Referenceelectrode | 3.8mol/LKCL |
Reference probes Picture:

Pre-sale service
24hours online to ensure quick response to customers' inquiry or online message;Guide customers to choose the best suitable machine model;
Offer detailed specification and competitive prices.
Contract execution
Machine production will be arranged strictly according to the contract;
Machine photo will be sent to you for inspection during production;
Send customs clearance documents by DHL;
Update latest news after delivery and prepare customs clearance.
After-sale service
12months warranty except for wear parts;
Broken spare parts(except for wear parts)will be sent for free due to quality problems;
In time response to customers technical problems;
New products update for customers' reference
FAQ
1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except wear parts. You can also buy parts from us after 12months.
Company Show
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Water Analysis Equipments
- Electrochemical Sensor/Electrode
- PF-202-C Fluoride (F-) Combined Ion Selective Electrode ISE Probe
Related Categories
Hot Searches
More