  • AA7090 Atomic Absorption Spectrometer with Ce
  • AA7090 Atomic Absorption Spectrometer with Ce
  • AA7090 Atomic Absorption Spectrometer with Ce
  • AA7090 Atomic Absorption Spectrometer with Ce
  • AA7090 Atomic Absorption Spectrometer with Ce
  • AA7090 Atomic Absorption Spectrometer with Ce
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Related Product
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
AA7090
Warranty
> 1Year
Detection Method
Spectrophotometer
Advantage
High Sensitive
Principle
Classic Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
RoHS, ISO9001, CE
Customized
Customized
Dimensions
1000*610*510mm,150kg
Power
220V / 50Hz 110V/60Hz
Instrument
200W
Graphite Furnace
4 Kw
Model
AA7090
Wavelength Range
190-900 Nm
Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0 Nm, Automatic Switch
Indication Error
+-0.1 Nm
Wavelength Repeatability
<= 0.05 Nm
Grating
1800 Lines / mm
Blaze Wavelength
250 Nm
Resolution
Better Than 0.1 Nm
Transport Package
Wooden Case
Specification
CE
Trademark
NANBEI
Origin
Zhengzhou, China
HS Code
8514109000
Production Capacity
300 Pieces/Month

Product Description

Product Description

NB-7090 Atomic Absorption Spectrometer

Application:
NB-7090 is the fifth-generation atomic absorption spectrometer developed by NANBEI. It combines the quality and precision that NANBEI is known for with important new features. The NB-7090 graphite furnace features a unique design with transverse heating, longitudinal Zeeman background correction and variable magnetic field intensity. The Zeeman background correction is suitable for high precision analysis of samples with complex interference matrices. Variable magnetic field intensity allows the operator to optimize field strength for each element, maximizing the Zeeman effect for accurate results every time.


NB-7090 - The new standard for high performance Zeeman GF analysis available in a flame tandem configuration.
  1. Transverse graphite furnace heating technology improves sample atomization efficiency and uniformity.
  2. Two background correction methods are available: longitudinal Zeeman effect correction and d*euterium lamp correction. The operator can select the most suitable mode based on the sample.
  3. Unique adjustable magnetic field strength (0.6 - 1.1 Tesla, in 0.1 Tesla increments) allows for element specific optimization to achieve high sensitivity and precision.
  4. 8-lamp automated lamp turret with auto-alignment for quick element switching and lamp position optimization
  5. Code lamp recognition technology, compatible with both hollow cathode lamps and super lamps
  6. High efficiency super lamp power supply, newly designed for higher sensitivity while consuming less power and generating less heat

Detailed Photos

AA7090 Atomic Absorption Spectrometer with Ce
AA7090 Atomic Absorption Spectrometer with Ce
AA7090 Atomic Absorption Spectrometer with Ce

Product Parameters

Unique functional design, easy to operate Automated burner head height control:
  1. The burner head height can be automatically adjusted using a software-controlled motor. This feature is used to ensure that the burner head can be accurately and reproducibly positioned on the optical path to optimize the performance of the
 
  1. The position of the burner head is stored with the analysis method parameters of each element in a multi-element flame analysis. During a sample run, each element will be analyzed at the optimal height without operator intervention. The following figure shows the sensitivity obtained when the burner head height of each element is separately optimized (purple) compared to the sensitivity obtained when the burner head height is optimized for only a single element, copper (cyan).
 
Coded lamp recognition: By simply inserting the element lamp into the lamp holder, the software will automatically identify the element and position of the lamp. This feature completely eliminates the possibility of operator error when inputting lamp information into the element lamp list.
Super lamp power supply: Super lamps are specially designed ultra-high intensity hollow cathode lamp that provide more optical energy. For certain elements, such as As, Se, Cd, Ni and Pb, super lamps can significantly improve the limit of detection, sensitivity and linearity.
AA-7090 atomic absorption spectrometer can be equipped with up to four super-lamp power supplies.
Graphite Furnace Viewing SystemL: The Graphite Furnace Viewing System uses a camera to view the flame or graphite furnace.

This feature is indispensable for the development of graphite furnace methods. The operator can observe the entire analysis process from injection to atomization in real time. Using visual information, the desolvation, drying and ashing parameters can be set correctly to produce reproducible and accurate results.
Graphite furnace gas saving mode: The intelligent control of the protection gas switch maximizes the effective use of protection gas and reduces waste when the gas is not needed, cutting down on the cost of operation.
Excellent performance, accurate results guaranteed
Cutting edge transverse heating, longitudinal Zeeman effect graphite furnace technology:
  1. Compared with transverse Zeeman effect graphite furnace designs, the longitudinal Zeeman effect graphite furnace has the advantage of not needing a polarizer located along the optical path. This results in a two-fold increase in the amount of energy reaching the detector, which provides higher sensitivity and better correction linearity. Transverse graphite furnace heating has the advantage of higher temperature and greater temperature distribution uniformity, which promotes atomization of the sample with high efficiency and uniformity.
  2. Efficient graphite furnace design and precise temperature control provides the user with a reliable and precisely controlled analysis environment. This allows the NB-7090 to perform automated multi-element, multi-sample analysis with excellent stability and repeatability.
  3. Additionally, a 2500 /sec maximum heating rate guarantees optimal atomization conditions for all elements.
Unique Variable Magnetic Field Strength: A constant magnetic field strength for all elements leads to severe limitations in analytical performance for many sample types. The AA-7090 achieves optimal background correction and sensitivity by allowing optimization of the magnetic field strength for each element/matrix combination. The applied magnetic field can be varied from a low of 0.6 to a high of 1.1 Tesla in increments of 0.1 Tesla. This allows the operator to set the optimum field strength for each element, maximizing the Zeeman Effect as measured through the magnetic sensitivity ratio (MSR).
Variable background correction allows the field strength to be adjusted to maximize both precision and sensitivity. This produces accurate results every time.
Unique double gas route: The NB-7090 features a unique double gas route design, with an inner gas route and an auxiliary gas route. Auxiliary gas is controlled through software. The addition of auxiliary gas promotes sample ashing and protects the graphite tube, allowing for more firings before replacement.
Two background correction modes: The operator can select between Zeeman effect, and d*euterium lamp background correction modes based on the requirements of a particular sample matrix.
 
Accessories:
NB-7090 works with NANBEI's furnace autosampler AS-500, and flame/furnace autosampler AS-600.
Also it can be used with NANBEI's hydride generator and other accessories.

Optics:
Wavelength Range: 190 nm ~ 900 nm
Bandwidth: 0.1, 0.2, 0.4, 1.0 and 2.0 nm, automatic switch
Czerny-Turner Grating Mono-chromator Wavelength Accuracy / Indication Error: ±0.1 nm Wavelength Repeatability: ≤ 0.05 nm
Grating: 1800 lines / mm Blaze Wavelength: 250 nm
Baseline Stability:Static baseline stability ≤ 0.002 A / 30 min, dynamic baseline stability ≤ 0.003 A / 30 min
Resolution: Better than 0.1 nm

Graphite Furnace System:
Characteristic Concentration of Cd: ≤ 0.5×10-12 g Detection Limit: ≤ 1×10-12 g RSD ≤ 3.0%
Temperature Control: Max 20 step temperature program. 3 modes of temperature rise: step, slope and flat.
Heating Mode: power heating Heating Rate: ≥ 2500 / s


Flame System:
Characteristic Concentration of Cu: ≤ 0.02 µg / mL / 1% Detection Limit: ≤ 0.003 µg / ml RSD ≤ 0.45%
Burner Head: Switchable 50 mm and 100 mm titanium burner head, titanium nebulizer and high performance glass nebulizer
Position Control: Optimization of height and angle, flame and hydride switch within one min


Background Correction:
Background correction is available for both flame and graphite furnace methods. D*euterium lamp for flame. d*euterium lamp or Zeeman for graphite furnace.

Correction Mode: D*euterium lamp, Zeeman Correction Capability:

  1. D*euterium lamp: When background absorption approaches 1.0 Abs, the instrument is capable of a background correction of 60 times or more.
  2. Zeeman: When background absorption approaches 2.0 Abs, the instrument is capable of a background correction of 100 times or more.
Data Processing:
Measurement Methods: Flame absorption, flame emission, graphite furnace, and hydride method.
Analysis Method: Linear fitting, nonlinear fitting, standard addition method.
Printing Output: Calibration curve, spectrum, analysis conditions, analysis parameters, and analysis results can be automatically stored and printed.

 

Packaging & Shipping

AA7090 Atomic Absorption Spectrometer with Ce

Related Product

AA7090 Atomic Absorption Spectrometer with Ce
AA7090 Atomic Absorption Spectrometer with Ce

 

Company Profile

AA7090 Atomic Absorption Spectrometer with Ce

Certifications

AA7090 Atomic Absorption Spectrometer with Ce

FAQ

24hours online to ensure quick response to customers' inquiry or online message;
· Guide customers to choose the best suitable machine model;
· Offer detailed specification and competitive prices;
Contract execution
· Machine production will be arranged strictly according to the contract;
· Machine photos will be sent to you for inspection during production;
· Send customs clearance documents by DHL;
· Update latest news after delivery and prepare customs clearance;
After-sale service
· 12 months warranty except for wear parts;
· Broken spare parts (except for wear parts) will be sent for free due to quality problems;