Lab Using Water Testing Conductivity Probe

Product Details
Customization: Available
Type: Conductivity Electrode
Cooling System: Fan, Radiator
Manufacturer/Factory, Trading Company, Group Corporation

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online
  • Lab Using Water Testing Conductivity Probe
  • Lab Using Water Testing Conductivity Probe
  • Lab Using Water Testing Conductivity Probe
  • Lab Using Water Testing Conductivity Probe
  • Lab Using Water Testing Conductivity Probe
  • Lab Using Water Testing Conductivity Probe
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Products
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
DJS series
Materials
Glass, Stainless Steel, Plastic
Name
Lab Using Water Testing Conductivity Probe
Waterproof
Yes
Temperature Compensation
Yes
Usage
Water Salinity Test
Measuring Range
2~20000 Us/Cm
Body Material
Glass
Size
12X120mm
Connector
5-Pin
Constructure
Two-Pole Piece Type
Work with
Conductivity Meter
Cell
1
Work Temperature
0~80 C
Transport Package
Export Standard Package
Specification
CE
Trademark
Nanbei
Origin
Zhengzhou, China
HS Code
9031809090
Production Capacity
2000000PCS Per Month

Product Description


Laboratory two-pole piece type conductivity probe

Product Description

Specifications:
Housing material: glass
Dimension (mm): Φ12×120

Product introduction:
Two-pole piece type conductivity electrode is used the most frequently in China, the structure of laboratory two-pole piece type conductivity electrode is to fire platinum sheet on parallel glass, or on wall of round glasstube,adjusting the area and distance of platinum sheet tomakeconductivity electrode with different constant. Platinum black electrode can efficiently avoid polarization
phenomenon when measure high conductivity solution.

Detailed Photos

Lab Using Water Testing Conductivity ProbeLab Using Water Testing Conductivity Probe

Product Parameters

Technical parameter:

EC Electrodes(1mS/cm=1000μS/cm)
Model Name Measurement Range Sensor material Working Temp. Dimension Connector
DJS-1VC Conductivity Electrode(k=1) 2~20000 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation
DJS-1VTC Conductivity Electrode(k=1, ATC) 2~20000 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation
DJS-1VG Conductivity Electrode(k=1) 2~3000 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation
DJS-1VTG Conductivity Electrode(k=1, ATC) 2~3000 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation
DJS-0.1VTG Conductivity Electrode(k=0.1, ATC) 0.05~200 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation
DJS-0.01VT Conductivity Electrode(k=0.01, ATC) 0.05~2 μS/cm Titanium alloy 0~80 ºC Φ18×50 mm 5-pin aviation
DJS-0.01VT(with removable flow cell) Conductivity Electrode(k=0.01, ATC, with removable flow cell) 0.05~2 μS/cm Titanium alloy 0~80 ºC Φ18×50 mm 5-pin aviation
DJS-10VTC Conductivity Electrode(k=10, ATC) 2000~200000 μS/cm Glass 0~80 ºC Φ12×120 mm 5-pin aviation

Note: The measuring range of conductivity sensor iseffected by instrument function and tested sample.

When ordering a DJS-0.01VT Conductivity Probe,please also order a cell for it. We can customize conductive composite electrode(built-intemperature),according to customer demand.

User guide of Conductivity Electrode
1. The main material for electrode measuring terminal is glass and platinum, make sure that test solutions will not affect measuring terminal before measurement.
2. The surface of platinum sheet of platinum black probe is adhered with loose platinum black substance, should avoid touching with any object. It is not suitable to measure the conductivity of solutions with high viscosity. Damage of platinum black substance may cause mismeasurement.
3. The constant of conductivity electrode should be calibrated regularly.
4. The electrode cap,wire and connector interface should avoid stress and any damage.
5. Must keep the connector interface dry.
6. Cleaning of platinum black conductivity electrode a) Routine cleaning: Immerse electrode measuring terminal in absolute ethanol and rinse several times, charge absolute ethanol twice during rinsing. Then soak the electrode in DI water for more than 20min. b) Inorganic sediment: Immerse the electrode measuring terminal in 1% acetic acid solution for 5min,then follow routine cleaning.
7. Put1/2DIwaterinprotectivebottletostoretheelectrode.
8. Cleaning and repair of bright conductivity electrode
a) Soak the electrode 0.1mol/LHCl or 0.1mol/LEDTA for 15min,then rinse with DI water. b) Organic cleaning:Immerse the electrode measuring terminal in absolutee than ol (or solvent that can dissolve this organic)for 15min,then rinse with DI water.

Related Products

Click the photo to get more details:

Lab Using Water Testing Conductivity Probe
Lab Using Water Testing Conductivity Probe
Lab Using Water Testing Conductivity Probe

Certifications

Lab Using Water Testing Conductivity Probe

Packaging & Shipping

Lab Using Water Testing Conductivity Probe
 

FAQ

 

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can you visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express .
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:

  1. Warranty : 1 year
  2. We supply free part for quality problem in warranty
  3. Long life technical support and service


 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More