• Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
  • Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
  • Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
  • Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
  • Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
  • Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components

After-sales Service: Online Permanent Technical Support
Warranty: 1year
Element: Metals Analyzer
Analysis: Infrared Analysis
Display: Computer Screen
Application: Metal
Customization:

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Product
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
AA4530F
Frequency
50±0.5Hz
Performance
Semi-automatic
Function
Measurement Metal Element
Weight
100-500Kg
Power Source
AC220V±22V
Customized
Customized
Product Name
Atomic Absorption Spectrophotometer Aas
Wl Range
190-900nm
Wl Accuracy
<0.15nm
Wl Repeatability
<0.04nm
Spectrum Bandwidth
0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm
Preciseness
0.5%
Characteristic Concentration of Copper
<0.02ug/Ml/1%
Detection Limit of Copper
<0.004ug/Ml
Grating
1800 Lines/mm
Inflamer
All-Metal Titanium Burner
Atomizer
Effective Glass Atomizer
Lamp Stand
8
D2 Background Correction Ability
Yes
Power Supply
220V 3A, 50Hz
G.W.
138kg / 116kg
Transport Package
Wooden Case
Specification
950 * 620 * 1020mm
Trademark
NANBEI
Origin
Zhengzhou, Henan, China
HS Code
9031809090
Production Capacity
500set/Month

Product Description

Product Description

AA4530F AAS Spectrophotometer
AA4530F Atomic Absorption Spectrophotometer Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
Characteristics
1. Completely controlled by PC.
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3.Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.
4.Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5.Fully automated wavelength scanning and peak searching.
6.Complete safety chains protection equipment: the function of warning and automatic safety protection towards  the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7.Deuterium lamp and self-absorption background regulation.
8.Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9.Measuring method: flame absorption method and emission method.
10.Result printing: parameter printing, data result printing and diagram printing

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer ComponentsComplete Automatic Controlling System

With the help of the software, the following can be easily achieved
* Selection of the element lamp
* Up-down-front-rear adjustment of the lifter
* Adjustment of the optical energy
* Selection of the slit
* Determination of wavelength scanning and peak searching
* Selection of the atomizer
*  Setting of the background deduction method
* Controlling of the gas flow
*Automatic flaming and flaming out
*Setting of the graphite furnace testing method

Advanced Graphite Furnace Tempera-Ture Controlling Technology
- The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. 
- The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data.
-The fast heating capacity can improve the flexibility of the elements further.
- Use the ordinary power source of 220V without need of dynamic power of 380V.
-The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples.
- Three grades adjustable gas flow can accustom to more application needs.
- Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error.

Detailed Photos

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components

 

Product Parameters

Model No AA4530F
Wavelength Range 190-900nm
Spectrum Bandwidth 0.1/0.2/0.4/1.0/2.0nm
Wavelength Accuracy ±0.15nm
Wavelength Receptivity ≤0.04nm
Baseline stability ±0.002Abs/30min(Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.50%
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp stand 8
D2 background correction ability self absorption background deduction method, when the background is 1A, the background ability should be deducted no less than 50 times
Power Supply AC 110-240V, 120W
Size and weight 700x550x450mm/75Kg
Flame system
Acetylene air burner 100mm
Ignition dynamic baseline drift ≤0.006Abs/30 min
(Cu) Characteristic viscosity 0.025μg/ml/1%
Related standard accuracy deviation ≤0.5%(Cu, absorbance>0.8A)(detection limit Cu ≤0.008μg/ml)
Safety system when pressure is insufficent, the system automatically cut off the gas and power off, flame out and unconformity of the burner
Graphite Furnace  
Temperature upper limit 3000ºC
Largest temperature rise speed ≥2000ºC/second
Characteristic quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Safety system Over current protection /Low air pressure alarm / protection
Low cooling water flow alarm/protection
Size and weight 550mm×450mm×300mm 65Kg

 

Related Product

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components

 

Packaging & Shipping

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer ComponentsAtomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components
 

Company Profile

Atomic Absorption Spectrophotometry Flame Atomic Absorption Spectrophotometer Components

FAQ

Q1: Why Choose NANBEI ?
(1).Professional manufacturer with more than 13 years experience
(2).Exported to more than 97% Countries
(3).Turnkey Solution is no problem

Q2:OEM,ODM acceptable or not?
Absolutely Yes

Q3:What's kind of Payment terms for customer choosing?
T/T ,Western Union, Money Gram , Credit Card, Paypal , L/C ...

Q4:Can we visit your factory online?
Absolutely no problem

Q5:Can online video inspection before shipment?
Absolutely no problem

Q6: what's the MOQ ? Sample order is OK?
MOQ:1 set, sample order is no problem

Q7:What's kind of shipment for customer choosing?
Usually ship by sea, by air, by international express.
We can also provide reasonable solutions according to your transportation requirements

Q8:How to ensure product quality and after-sales service?
We have CE, ISO quality certificate, and SGS authentication.

After-sale service:
1.Warranty:1 year
2.We supply free part for quality problem in warranty
3.Long life technical support and service

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online