• Gc112A Gas Phase / Liquid Chromatography with CE
  • Gc112A Gas Phase / Liquid Chromatography with CE
  • Gc112A Gas Phase / Liquid Chromatography with CE
  • Gc112A Gas Phase / Liquid Chromatography with CE
  • Gc112A Gas Phase / Liquid Chromatography with CE
  • Gc112A Gas Phase / Liquid Chromatography with CE

Gc112A Gas Phase / Liquid Chromatography with CE

After-sales Service: on Line Service
Warranty: One Year
Appliance: Food Analysis
Ray Type: Gamma Ray Spectrometer
Gaspath System: Three
Detector: TCD
Customization:

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Related Product
  • Packaging & Shipping
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
GC112A
Energy Resolution
≤7%
Certification
CE, ISO
Spectrometer Detector
SDD
Stationary Phase
Gas or Liquid
Mobile Phase
Gas
Chromatography Type
Gas Chromatography
Chromatographic Column Type
Capilary Column
Chromatographic Column Length
10~30cm
Chromatographic Column Diameter
1~2mm
Temperature Control
Max. 420 Degree
Number of Same Time Installations
2 at Most
Ignition Function
Automatic
Hydrogen Flame Ionization Detector
(Fid)
Detection Limit
Less Than 3*10 G/S (N-Hexadecane)
Baseline Noise
Less Than 5*10-14A
Baseline Drift
Less Than 6* 10-13A
Dynamic Range
107
Rsd
3% or Less
Thermal Conductivity Detector
Tcd
Sensitivity
5000mv * Ml/Mg (N-Cetane)
Baseline Noise 2
Less Than 0.05 Mv
Baseline Drift 2
Less Than 0.15mv 30min
Dynamic Range 2
105
Transport Package
Hard Wooden Case
Specification
CE
Trademark
NANBEI
Origin
Zhengzhou, China
HS Code
9027201100
Production Capacity
100 Pieces/Month

Product Description

Product Description

GC112A Gas phase / liquid chromatography:

 Basic principles of gas chromatography:


Gas chromatography is a chromatographic separation analysis method that uses gas as a mobile phase. The vaporized sample is carried by the carrier gas (mobile phase) into the chromatographic column. The stationary phase in the column has different molecular forces from the components in the sample, and the time for each component to flow out of the chromatographic column is different, and the components are separated from each other. Using an appropriate identification and recording system, make a chromatogram that marks the time and concentration of each component flowing out of the chromatographic column. According to the peak time and sequence indicated in the figure, the compound can be qualitatively analyzed; according to the height and area of the peak, the compound can be quantitatively analyzed. It has the feather  of high efficiency, high sensitivity, strong selectivity, fast analysis speed, wide application, simple operation and so on. Suitable for qualitative and quantitative analysis of volatile organic compounds.

Application:
As long as the substance can be vaporized without decomposition under the conditions allowed by the gas chromatograph, it can be determined by gas chromatography. For some thermally unstable substances, or substances that are difficult to vaporize, through chemical  methods, gas chromatography can still be used for analysis. It has been widely used in petrochemical, medical and health, environmental monitoring, biochemistry, food testing and other fields

1. Application in sanitary inspection Air and water pollutants such as volatile organic compounds, polycyclic aromatic hydrocarbons, benzene, toluene, benzo(a) ratio, etc.; residual organochlorine and organophosphorus pesticides in crops; food additives, benzoic acid, etc.; biological materials such as body fluids and tissues Analysis such as amino acids, fatty acids, vitamins, etc.

2. Application in medical laboratory Analysis of biological materials such as body fluids and tissues: such as fatty acids, triglycerides, vitamins, sugars, etc.

3. Application in drug analysis Determination of volatile components in antiepileptic  drugs, Chinese patent medicines, and alkaloids, etc.


The basic composition of the instrument: Sampling system + chromatographic column + detector + chromatographic

Workstation software Sampling system: divided into capillary column sampling system and packed column sampling system

Chromatographic column: divided into packed column and capillary column.

Detector: FID (hydrogen flame) detector; TCD (thermal conductivity) detector; ECD (electron capture).detector; FPD (flame photometric) detector.

Chromatography workstation: divided into ordinary workstation and special version workstation.


 

FID Detector

Volatile hydrocarbons (such as organic solvents, alcohols, esters, ketones, etc.)

TCD Detector

Moisture, various gases, volatile organic compounds, etc.

ECD Detector

Halogenated hydrocarbon compounds (such as organochlorine pesticides, chloroform, carbon tetrachloride, etc.)

FPD Detector

Sulfur-containing and phosphorus-containing compounds (such as hydrogen sulfide, methyl phosphorus, etc.)


Technical features:

 The host has the memory and recall function of 20 sets of sample test methods    

 (In the past, we usually record the condition of the test sample in the sample map and output it to the electronic file. When the sample is to be remade, it must be manually input and adjusted according to the requirements of the sample test, especially in the gas circuit part. The workload is very large. Now just recall the previous storage directly, and the rest of the instrument will be completed automatically)


 Standard PC side reverse control software, built-in chromatographic workstation, achieve PC side reverse control and host touch screen same time double directional control. (GC112N only):

1.Host with 7-inch color touch screen, carrier/hydrogen/air channel flow (pressure) digital display.
2. Gas shortage alarm protection function; Heating control protection function (when opening the door of the column box, the motor of the column box fan and the heating system will shut down automatically).
3.Split flow/split ratio can be automatically controlled to save carrier gas.
4.Configure automatic sampler installation and positioning interface to match automatic sampler of various specifications.
5.The multi-core, 32-bit embedded hardware system ensures  the reliable operation of the instrument.
6.One-button start function, with 20 groups of sample test mode memory function.
7.Using logarithmic amplifier, detection signal no     cut-off value, good peak shape, extensible     same time external trigger function, can be started     by external signals (automatic sampler, thermal     analyzer, etc.) at the same time the host and workstation.
8. It has perfect system self-check function and fault    automatic identification function.
9. With 8 external event extension function interface,    can be selected with various function control valves,    and according to their own set time sequence work.
10.RS232 communication port and LAM network port,    and the configuration of data learn card. Column temperature box:
11.Content product: 22L
12.Temperature control range: 5ºC ~ 400ºC at room temperature.


Column temperature box:
1. Temperature control accuracy: ±0.1ºC
2. Heating rate: 0.1 ~ 60ºC / min
3. Program temperature rise  steps: 9
4. Program heating repeatability: ≤ 2%
5. Cooling way: open the door after
6. Cooling speed: ≤10 mins (250ºC ~ 50ºC) Control software function :(GC112N only)
7. Column temperature box control
8. Detector control
9. Injector control
10. Map display


Detector:
1.FID, TCD optional one
2.Temperature control range: room temperature 7 ºC - 420 ºC
3.Number of simultaneous installations: up to 2
4.Ignition function: automatic
5.Hydrogen flame ionization detector (FID):
6.Detection limit: ≤ 3 × 10-12 g / s (n-hexadecane)
7.Baseline noise: ≤ 5 × 10-14 A
8.Baseline drift: ≤ 6 × 10-13 A
9.Dynamic range: 107
10.RSD: ≤ 3%
11.Thermal Conductivity Detector (TCD):
 12.Sensitivity: 5000mV.ml / mg (n-hexadecane)
  13.Baseline noise: ≤ 0.05 mV
  14.Baseline drift: ≤ 0.15 mV / 30 min
  15.Dynamic range: 105
16. Power supply voltage: 220V ± 22V, 50Hz ± 0.5Hz
 17.Power: 3000W

 

Detailed Photos

Gc112A Gas Phase / Liquid Chromatography with CE

Product Parameters

Column oven:

Inner volume  22L
Temperature range  5 ºC - 400 ºC at room temperature
 Temperature control accuracy  ± 0.1 ºC
 Heating rate  0.1 - 60 ºC / min
 The order of heating of the program  9
 Program temperature repeatability  ≤ 2%
 cooling method  after the door
 Cooling rate  ≤ 10 mins (250 ºC -50 ºC)
 
Sampler:
Temperature control range  room temperature 7 ºC - 420 ºC
 Temperature control mode  independent temperature control
 Carrier gas flow control mode  constant pressure
 Number of simultaneous installations  up to 3
 Injection unit type  packed column, shunt
 Split ratio  Split ratio display
Stigma pressure range  0 - 400kpa
 Stem pressure control accuracy  0.1kpa
 Flow setting range  H20-200ml / min N20-150ml / min

 

Related Product
Gc112A Gas Phase / Liquid Chromatography with CE
Gc112A Gas Phase / Liquid Chromatography with CE

 

Packaging & Shipping

Gc112A Gas Phase / Liquid Chromatography with CE

Company Profile

Gc112A Gas Phase / Liquid Chromatography with CE

Certifications

Gc112A Gas Phase / Liquid Chromatography with CE

FAQ

1. How can I choose the suitable one?

Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

 

Pre-sale service

· 24hours online to ensure quick response to customers' inquiry or online message;

· Guide customers to choose the best suitable machine model;

· Offer detailed specification and competitive prices;

Contract execution

· Machine production will be arranged strictly according to the contract;

· Machine photos will be sent to you for inspection during production;

· Send customs clearance documents by DHL;

· Update latest news after delivery and prepare customs clearance;

After-sale service

· 12 months warranty except for wear parts;

· Broken spare parts (except for wear parts) will be sent for free due to quality problems;

· In time response to customers technical problems;

· New products update for customers' reference.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
Management System Certification
ISO 9001, ISO 9000, ISO 20000, HSE
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment, Money Gram, pay online